Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope
Authors:
- Roberto A. SantilliRSRoberto A. Santilli
- Luca FerasinLFLuca Ferasin
- Simona G. VogheraSVSimona G. Voghera
- Manuela PeregoMPManuela Perego
- 1 January 2010
- journal article
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 236 (1) , 78-82
Abstract
Objective—To evaluate the diagnostic value of an implantable loop recorder (ILR) in dogs with unexplained syncope. Design—Prospective case series. Animals—12 dogs with recurrent unexplained syncope. Procedures—An ILR was surgically inserted in a pocket created in the subcutaneous tissues of the left hemithorax of each dog. The ILRs were programmed for manual and automatic activation, and event analysis and programming were performed at 3-month intervals and after each syncopal episode. Results—The ILR was manually activated in 7 of 12 dogs at least once within 45 to 218 days (median, 120 days) after implantation. Four dogs had syncopal episodes associated with sinus tachycardia followed by sinus bradycardia and asystolic pauses. Two dogs had ventricular tachycardia, and 1 dog had sinus node dysfunction with prolonged sinus arrest that coincided with loss of consciousness and falling. Four dogs had no additional syncopal episodes after implantation of the ILR. In the remaining dog, the owner was unable to activate the ILR during the only syncopal episode observed for that dog after ILR implantation. In all 12 dogs, analysis of ECG traces after automatic activation of recording revealed normal cardiac rhythms. Conclusions and Clinical Relevance—Data gained after manual activation of an ILR provided valuable diagnostic and prognostic information in almost all dogs with unexplained syncopal episodes by confirming or disproving an association between syncope and arrhythmias. However, detection of disturbances in cardiac rhythm after automatic activation did not appear to improve the diagnostic value for an ILR implanted in dogs.Keywords
This publication has 12 references indexed in Scilit:
- Recurrent syncope associated with paroxysmal supraventricular tachycardia in a Devon Rex cat diagnosed by implantable loop recorderJournal of Feline Medicine and Surgery, 2009
- Implantable loop recorders: a viable diagnostic tool in veterinary medicineJournal of Small Animal Practice, 2008
- How Revealing Are Insertable Loop Recorders in Pediatrics?Pacing and Clinical Electrophysiology, 2008
- Implantable loop recorder in unexplained syncope: classification, mechanism, transient loss of consciousness and role of major depressive disorder in patients with and without structural heart diseaseHeart, 2007
- Cardiovascular Device Infections in Dogs: Report of 8 Cases and Review of The LiteratureJournal of Veterinary Internal Medicine, 2007
- Seizure versus syncopeThe Lancet Neurology, 2006
- AHA/ACCF Scientific Statement on the Evaluation of SyncopeCirculation, 2006
- Insertable Loop Recorder Use for Detection of Intermittent ArrhythmiasPacing and Clinical Electrophysiology, 2004
- Use of the Implantable Loop Recorder in Evaluation of Patients with Unexplained SyncopeJournal of Cardiovascular Electrophysiology, 2003
- RECURRENT SYNCOPECardiology Clinics, 1997