Phase-Based Methods for Heart Rate Detection Using UWB Impulse Doppler Radar
- 18 August 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (10) , 3319-3331
Abstract
Ultra-wideband (UWB) pulse Doppler radars can be used for noncontact vital signs monitoring of more than one subject. However, their detected signals typically have low signal-to-noise ratio (SNR) causing significant heart rate (HR) detection errors, as the spurious harmonics of respiration signals and mixed products of respiration and heartbeat signals (that can be relatively higher than heartbeat signals) corrupt conventional fast Fourier transform spectrograms. In this paper, we extend the complex signal demodulation (CSD) and arctangent demodulation (AD) techniques previously used for accurately detecting the phase variations of reflected signals of continuous wave radars to UWB pulse radars as well. These detection techniques reduce the impact of the interfering harmonic signals, thus improving the SNR of the detected vital sign signals. To further enhance the accuracy of the HR estimation, a recently developed state-space method has been successfully combined with CSD and AD techniques and over 10 dB improvements in SNR is demonstrated. The implementation of these various detection techniques has been experimentally investigated and full error and SNR analysis of the HR detection are presented.Keywords
This publication has 35 references indexed in Scilit:
- Estimation of Cardiopulmonary Parameters From Ultra Wideband Radar Measurements Using the State Space MethodIEEE Transactions on Biomedical Circuits and Systems, 2016
- Overview of vital sign detection-simulation and measurements2016
- UWB baby and sleep apnea monitor2015
- Short time state space method for human motion identification2015
- A Self-Calibrating Radar Sensor System for Measuring Vital SignsIEEE Transactions on Biomedical Circuits and Systems, 2015
- Noncontact Distance and Amplitude-Independent Vibration Measurement Based on an Extended DACM AlgorithmIEEE Transactions on Instrumentation and Measurement, 2013
- UWB micro-doppler radar for human gait analysis using joint range-time-frequency representation2013
- Towards Low Cost, High Speed Data Sampling Module for Multifunctional Real-Time UWB RadarIEEE Transactions on Aerospace and Electronic Systems, 2013
- Data-Based Quadrature Imbalance Compensation for a CW Doppler Radar SystemIEEE Transactions on Microwave Theory and Techniques, 2013
- Wireless Sensing of Human Respiratory Parameters by Low-Power Ultrawideband Impulse Radio RadarIEEE Transactions on Instrumentation and Measurement, 2010