Transmission Comparison for Cooperative Robotic Applications
Open Access
Abstract
The development of powered assistive devices that integrate exoskeletal motors and muscle activation for gait restoration benefits from actuators with low backdrive torque. Such an approach enables motors to assist as needed while maximizing the joint torque muscles, contributing to movement, and facilitating ballistic motions instead of overcoming passive dynamics. Two electromechanical actuators were developed to determine the effect of two candidate transmission implementations for an exoskeletal joint. To differentiate the transmission effects, the devices utilized the same motor and similar gearing. One actuator included a commercially available harmonic drive transmission while the other incorporated a custom designed two-stage planetary transmission. Passive resistance and mechanical efficiency were determined based on isometric torque and passive resistance. The planetary-based actuator outperformed the harmonic-based actuator in all tests and would be more suitable for hybrid exoskeletons.Keywords
Funding Information
- National Science Foundation (1739800)
- U.S. Department of Veterans Affairs (1I01RX002275-01)
This publication has 37 references indexed in Scilit:
- Pilot study of locomotion improvement using hybrid assistive limb in chronic stroke patientsBMC Neurology, 2013
- Mobility training using a bionic knee orthosis in patients in a post-stroke chronic state: a case seriesJournal of Medical Case Reports, 2012
- Efficacy of a hybrid assistive limb in post-stroke hemiplegic patients: a preliminary reportBMC Neurology, 2011
- Who wants to walk? Preferences for recovery after SCI: a longitudinal and cross-sectional studySpinal Cord, 2008
- Simulation of a functional neuromuscular stimulation powered mechanical gait orthosis with coordinated joint lockingIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Targeting Recovery: Priorities of the Spinal Cord-Injured PopulationJournal of Neurotrauma, 2004
- Preliminary evaluation of a controlled-brake orthosis for FES-aided gaitIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2003
- Comfortable and maximum walking speed of adults aged 20—79 years: reference values and determinantsAge and Ageing, 1997
- A nonlinear model of a harmonic drive gear transmissionIEEE Transactions on Robotics and Automation, 1996
- Recruitment, force and fatigue characteristics of quadriceps muscles of paraplegics isometrically activated by surface functional electrical stimulationJournal of Biomedical Engineering, 1990