Detection of Occult Endoleaks After Endovascular Treatment of Abdominal Aortic Aneurysm Using Magnetic Resonance Imaging With a Blood Pool Contrast Agent
Authors:
- Sandra A. P. CornelissenSCSandra A. P. Cornelissen
- Mathias ProkopMPMathias Prokop
- Hence J. VerhagenHVHence J. Verhagen
- Miraude E. AdriaensenMAMiraude E. Adriaensen
- Frans L. MollFMFrans L. Moll
- Lambertus W. BartelsLBLambertus W. Bartels
- 1 September 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 45 (9) , 548-553
Abstract
To determine whether blood pool contrast agent-enhanced magnetic resonance imaging (MRI) can visualize endoleaks that are occult on computed tomography (CT) in patients with nonshrinking aneurysms after endovascular aneurysm repair. Written informed consent was obtained for this prospective institutional review board approved study. Twelve patients with nonshrinking aneurysms but no evidence of endoleak on CT angiography and delayed CT underwent MRI with a blood pool contrast agent (Gadofosveset trisodium, Bayer Schering Pharma, Berlin, Germany). Patients could participate once in the study. T1-weighted images were acquired before injection, 3 minutes and 30 minutes after injection. Two blinded readers independently scored the images into "endoleak," "possible endoleak," or "no endoleak" by comparing postcontrast MR images with precontrast images. Weighted kappas with linear weighting scheme were calculated for interobserver agreement. One MRI examination was nondiagnostic because of patient motion. In the successful 11 MRI exams, MRI 3 minutes after injection demonstrated endoleak in 2/11 MRI exams (18%) and possible endoleak in 2/11 MRI exams (18%). After 30 minutes, MRI demonstrated endoleak in 6/11 scans (55%) and possible endoleak in 1/11 scans (9%). Weighted kappa was 0.78 and 0.89 for early and late postcontrast images. Endoleaks that are occult on CT can be detected by MRI with blood pool contrast agents. Late phase MRI 30 minutes after injection revealed additional endoleaks not seen 3 minutes after injection.Keywords
This publication has 25 references indexed in Scilit:
- The effect of endograft relining on sac expansion after endovascular aneurysm repair with the original-permeability Gore Excluder abdominal aortic aneurysm endoprosthesisJournal of Vascular Surgery, 2007
- Abdominal Aortic Aneurysm: Can the Arterial Phase at CT Evaluation after Endovascular Repair Be Eliminated to Reduce Radiation Dose?Radiology, 2006
- Multidetector CT in Abdominal Aortic Aneurysm Treated with Endovascular Repair: Are Unenhanced and Delayed Phase Enhanced Images Effective for Endoleak Detection?Radiology, 2006
- Detection of Endoleaks after Endovascular Repair of Abdominal Aortic Aneurysm: Value of Unenhanced and Delayed Helical CT AcquisitionsRadiology, 2003
- Early Changes in Abdominal Aortic Aneurysm Diameter after Endovascular RepairJournal of Vascular and Interventional Radiology, 2003
- Aneurysm Expansion after Stent-Graft Placement in the Absence of EndoleakJournal of Vascular and Interventional Radiology, 2002
- Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: The EUROSTAR experienceJournal of Vascular Surgery, 2002
- What are the Causes of Endotension?Journal of Endovascular Therapy, 2001
- Prospective Evaluation of Magnetic Resonance Imaging After Endovascular Treatment of Infrarenal Aortic AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2001
- Type III and Type IV Endoleak: Toward a Complete Definition of Blood Flow in the Sac After Endoluminal AAA RepairJournal of Endovascular Surgery, 1998