On-line photoassisted vapour generation implemented in an automated flow-injection/stopped-flow manifold coupled to an atomic detector for determination of selenium
- 3 May 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 21 (6) , 582-587
Abstract
A flow-through UV reactor has been implemented in an automated flow-injection/stopped-flow manifold, and used for on-line generation of Se volatile derivatives prior to detection by quartz furnace atomic absorption spectrometry. The presence of a low molecular weight organic acid (formic or acetic) in the carrier was a necessary requirement so that efficient vapour generation was achieved. Stopped-flow conditions were employed with the aim of increasing the time for which the sample zone was subjected to UV irradiation while it was transported to the detector. The simultaneous formation of H2 during the photochemical decomposition of formic acid facilitated the atomization of the Se derivatives in the quartz furnace, and therefore the addition of H2 to the carrier gas, which is necessary for efficient atomisation, could be eliminated. Nevertheless, the presence of H2 in the carrier gas (Ar) was required for efficient atomisation when using acetic acid as carrier. This manifold allowed a sample throughput of 26 h−1 with a detection limit of 0.5 ng mL−1 Se and a repeatability, expressed as relative standard deviation, of 4%. Effect of concomitants in the online generation of Se vapours with the new manifold was investigated. Chloride salts of alkaline and alkaline-earth elements did not interfere at concentrations up to 10 000 mg L−1, but nitrate salts caused a positive effect. Tolerance of typical hydride-forming elements such as As and Sn was much higher with UV vapour generation as compared to chemical hydride generation. The presence of Cu(II) was critical since interference effects are observed from 0.05 mg L−1, but tolerance of Ni(II) was greater with UV vapour generation.Keywords
This publication has 35 references indexed in Scilit:
- Chemical vapor generation: are further advances yet possible?Analytical and Bioanalytical Chemistry, 2005
- Study of chemical and spectral interferences in the simultaneous determination of As, Bi, Sb, Se and Sn by hydride generation inductively coupled plasma atomic emission spectrometryAnalytica Chimica Acta, 2002
- Analytical Applications of Volatile Metal DerivativesApplied Spectroscopy, 2002
- Electrolytic hydride generation (EC-HG)—a sample introduction system with some special featuresJournal of Analytical Atomic Spectrometry, 2001
- Advantages and analytical applications of chloride generation. A review on vapor generation methods in atomic spectrometryMicrochemical Journal, 2000
- Heterogeneous photocatalysis: fundamentals and applications to the removal of various types of aqueous pollutantsCatalysis Today, 1999
- New Developments in Flow Injection Vapor Generation Atomic Absorption SpectrometryMicrochemical Journal, 1996
- Determination of chromium, cobalt, and iron by flame-atomic absorption spectrophotometry using volatilization of metal trifluoroacetyl acetonatesMicrochemical Journal, 1990
- Graphite furnace atomic absorption spectrometric determination of nickel at sub-ng g–1levels in marine samples by carbonyl generation with in situ pre-concentrationJournal of Analytical Atomic Spectrometry, 1989
- Determination of osmium by inductively coupled plasma emission spectrometry with an oxide generation/condensation systemAnalytical Chemistry, 1988