Assessment of superior vena cava flow and cardiac output in different patterns of patent ductus arteriosus shunt
- 26 July 2021
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 38 (9) , 1524-1533
Abstract
Background: Despite the widespread use of superior vena cava (SVC) flow as a marker of systemic blood flow from the upper body, no previous studies have systematically evaluated the correlation between SVC flow and other echocardiography measures of systemic blood flow in the context of different patterns of patent ductus arteriosus (PDA) shunt directionMethods: A retrospective cohort study of preterm infants (< 30 weeks, < 21 days of life) who underwent comprehensive targeted neonatal echocardiography (TnECHO) was performed. Patients were categorized as follows: (i) Hemodynamically significant left‐to‐right shunt; (ii): Bidirectional shunt; (iii) No PDA or insignificant shunt. SVC flow, as measured by two distinct methods, was compared to left and right ventricular outputs (LVO and RVO). Intra‐ and inter‐observer reliability testing was performedResults: In total, 45 patients were included (15 in each group) with a median [IQR] weight of 720 [539, 917] grams at the time of assessment. SVC dimensions and flow measurements were not different between the groups, although patients with left‐to‐right shunt had higher LVO/RVO ratio. SVC flow, as estimated using the modified method, had a strong correlation with LVO (r = .63, p = 0.012) and RVO (r = .635, p = 0.011) in patients with no PDA. Inter‐ and intra‐observer reliability were both stronger for LVO and RVO when compared to SVC flow measurementsConclusion: SVC flow was comparable across all three groups irrespective of higher LVO and LVO/RVO ratio in patients with left‐to‐right shunts. This may reflect poor measurement reliability or compensation for left‐to‐right ductal shunt by increased LVO to maintain systemic perfusion.Keywords
This publication has 37 references indexed in Scilit:
- The diagnostic value of a single measurement of superior vena cava flow in the first 24 h of life in very preterm infantsEuropean Journal of Pediatrics, 2012
- Targeted Neonatal Echocardiography in the Neonatal Intensive Care Unit: Practice Guidelines and Recommendations for TrainingJournal of the American Society of Echocardiography, 2011
- Systolic Right Ventricular Function in Preterm and Term Neonates: Reference Values of the Tricuspid Annular Plane Systolic Excursion (TAPSE) in 258 Patients and Calculation of Z-Score ValuesNeonatology, 2011
- Central blood flow measurements in stable preterm infants after the transitional periodArchives of Disease in Childhood - Fetal and Neonatal Edition, 2010
- Cerebral and Splanchnic Hemodynamics after Duct Ligation in Very Low Birth Weight InfantsThe Journal of Pediatrics, 2009
- Bedside detection of low systemic flow in the very low birth weight infant on day 1 of lifeEuropean Journal of Pediatrics, 2008
- Echocardiographic assessment of blood flow volume in the superior vena cava and descending aorta in the newborn infantArchives of Disease in Childhood - Fetal and Neonatal Edition, 2007
- Low superior vena cava flow and neurodevelopment at 3 years in very preterm infantsThe Journal of Pediatrics, 2004
- Doppler echocardiographic measurement of pulmonary artery pressure from ductal Doppler velocities in the newbornJACC, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986