Antibacterial Efficacy of Accelerated Photoactivated Chromophore for Keratitis–Corneal Collagen Cross-linking (PACK-CXL)

Authors:

Abstract
PURPOSE: To investigate whether optimized photoactivated chromophore for keratitis–corneal collagen cross-linking (PACK-CXL) treatment settings allow accelerating treatment while maintaining antibacterial efficacy.METHODS: Staphylococcus aureusandPseudomonas aeruginosastrains were irradiated with ultraviolet-A light of equal fluence but different intensity settings (18 mW/cm2for 5 minutes and 36 mW/cm2for 2.5 minutes). The killing rate was determined by comparing the number of colony-forming units between cross-linked specimens and non-irradiated controls. The potential additional effect of 0.001% benzalkonium chloride was also investigated.RESULTS: The killing rates forStaphylococcus aureuswere 92.5% ± 5.5% (5 minutes at 18 mW/cm2) and 94.4% ± 2.9% (2.5 minutes at 36 mW/cm2). ForPseudomonas aeruginosa, the killing rates were 93.2% ± 8.3% (5 minutes at 18 mW/cm2) and 92.9% ± 5.0% (2.5 minutes at 36 mW/cm2). The presence of benzalkonium chloride in the riboflavin solution did not increase the killing rate significantly.CONCLUSIONS: The antibacterial efficacy of PACK-CXL follows the Bunsen–Roscoe law of reciprocity and can be maintained even when the irradiation intensity is considerably increased. These optimized settings may allow a shortened treatment time in the future for PACK-CXL and thus help facilitate the transition from the operating room to the slit lamp for treatment.[J Refract Surg. 2014;30(12):850–854.]

This publication has 33 references indexed in Scilit: