Air in the cavernous sinus following scalp vein cannulation
Authors:
- 1 March 1994
- journal article
- case report
- Published by Wiley in Anaesthesia
- Vol. 49 (3) , 219-220
Abstract
Summary: A 7‐month‐old infant was found to have air in the cavernous sinus during a CT scan under general anaesthesia. An anterior scalp vein had been used to administer atracurium and contrast. The anatomy and precautions to prevent air embolism during scalp vein cannulation are discussed.Keywords
This publication has 1 reference indexed in Scilit:
- Iatrogenic air in the cavernous sinus.American Journal of Roentgenology, 1992