Validity of Heart Rate-Based Models for Estimating Oxygen Uptake During Tennis Play
Authors:
- 1 November 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Strength & Conditioning Research
- Vol. 34 (11) , 3208-3216
Abstract
Baiget, E, Iglesias, X, and Rodríguez, FA. Validity of heart rate-based models for estimating oxygen uptake during tennis play. J Strength Cond Res 34(11): 3208–3216, 2020—This study aimed to assess the validity of an on-court tennis test (specific endurance tennis test [SET-Test]) and 2 heart rate (HR)-based methods for estimating oxygen uptake (V̇o 2) in competitive tennis players. Thirty-five male players performed a SET-Test to relate test duration (minutes) and V̇o 2. Two weeks later, 16 players performed a simulated match play set where HR and V̇o 2 (V̇o 2-PLAY, criterion value) were measured and then compared with V̇o 2 values predicted from the HR/V̇o 2 linear regression equations derived from the SET-Test (pV̇o 2-TEST) and from the one set match play (pV̇o 2-PLAY). Test duration and V̇o 2-TEST were strongly correlated (r 2 = 0.821, p < 0.001, SE E = 5.6 ml·kg−1·min−1), indicating that SET-Test outcome is a somewhat good indicator of aerobic fitness in tennis players, likely to be useful for training purposes. pV̇o 2-PLAY and V̇o 2-PLAY (criterion value) were strongly correlated (r 2 = 0.832, p < 0.001) and SE E was moderate (3.5 ml·kg−1·min−1 = 11.5%). pV̇o 2-TEST differed from the criterion (32.4 ± 10.7 vs. 30.8 ± 8.6 ml·kg−1·min−1, p < 0.001) and, although strongly correlated (r 2 = 0.689, p < 0.001), an overestimation occurred (mean Δ = 1.6 ml·kg−1·min−1 = 4.9%), yielding a high SE E (4.8 ml·kg−1·min−1 = 15.6%). We conclude that (a) SET-Test performance is a valid and moderately accurate predictor of V̇o 2; and (b) the individual HR-V̇o 2 regression equation generated during tennis match play predicts V̇o 2 with greater accuracy than the regression derived from the SET-Test.Keywords
This publication has 34 references indexed in Scilit:
- Maximal Aerobic Frequency of Ball Hitting: A New Training Load Parameter in TennisJournal of Strength & Conditioning Research, 2017
- Aerobic Fitness and Technical Efficiency at High Intensity Discriminate between Elite and Subelite Tennis PlayersInternational Journal of Sports Medicine, 2016
- Tennis Play Intensity Distribution and Relation with Aerobic Fitness in Competitive PlayersPLOS ONE, 2015
- Heart Rate Deflection Point Relates to Second Ventilatory Threshold in a Tennis TestJournal of Strength & Conditioning Research, 2015
- On-Court Endurance and Performance Testing in Competitive Male Tennis PlayersJournal of Strength & Conditioning Research, 2014
- Energy Expenditure During Tennis Play: A Preliminary Video Analysis and Metabolic Model ApproachJournal of Strength & Conditioning Research, 2011
- Tennis ranking related to exercise capacity: Figure 1British Journal of Sports Medicine, 2008
- Gender effect on the relationship of time limit at 100% ??VO2max with other bioenergetic characteristicsMedicine & Science in Sports & Exercise, 1996
- Reproducibility of running time to exhaustion at &OV0312;O2max in subelite runnersMedicine & Science in Sports & Exercise, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986