Welded tie plate feasibility study for ITER central solenoid structure

Authors:

Abstract
The result of a Nitronic 50 (N50) weld-screening program conducted in support of CS-Tie Plate Structure Design and Development is reported here. The goal of this program is to evaluate four different weld practices and to select the best weld practice for thick section welding of the N50 tie plate structure. The structure design specifies both the weld and base metals have the same minimum mechanical properties requirements. The criteria for selecting the best weld practice are based on the combination of the 295 K tensile properties and the 4 K-tensile, fatigue, and fracture-toughness properties.