Comparative Performances of HIV-1 RNA Load Assays at Low Viral Load Levels: Results of an International Collaboration
Open Access
- 1 February 2014
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 52 (2) , 517-523
Abstract
Low-level viremia during antiretroviral therapy and its accurate measurement are increasingly relevant. Here, we present an international collaboration of 4,221 paired blood plasma viral load (pVL) results from four commercial assays, emphasizing the data with low pVL. The assays compared were the Abbott RealTime assay, the Roche Amplicor assay, and the Roche TaqMan version 1 and version 2 assays. The correlation between the assays was 0.90 to 0.97. However, at a low pVL, the correlation fell to 0.45 to 0.85. The observed interassay concordance was higher when detectability was defined as 200 copies/ml than when it was defined as 50 copies/ml. A pVL of ∼100 to 125 copies/ml by the TaqMan version 1 and version 2 assays corresponded best to a 50-copies/ml threshold with the Amplicor assay. Correlation and concordance between the viral load assays were lower at a low pVL. Clear guidelines are needed on the clinical significance of low-level viremia.Keywords
This publication has 42 references indexed in Scilit:
- Cross-Platform Analysis of HIV-1 RNA Data Generated by a Multicenter Assay Validation Study with Wide Geographic RepresentationJournal of Clinical Microbiology, 2012
- British HIV Association guidelines for the treatment of HIV‐1‐positive adults with antiretroviral therapy 2012HIV Medicine, 2012
- Impact of Low-Level-Viremia on HIV-1 Drug-Resistance Evolution among Antiretroviral Treated-PatientsPLOS ONE, 2012
- HIV-1 low-level viraemia assessed with 3 commercial real-time PCR assays show high variabilityBMC Infectious Diseases, 2012
- Cost Ramifications of Increased Reporting of Detectable Plasma HIV-1 RNA Levels by the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Version 1.0 Viral Load TestJAIDS Journal of Acquired Immune Deficiency Syndromes, 2010
- Impact of Discrepancies between the Abbott RealTime and Cobas TaqMan Assays for Quantification of Human Immunodeficiency Virus Type 1 Group M Non-B SubtypesJournal of Clinical Microbiology, 2009
- Increased Detectability of Plasma HIV‐1 RNA after Introduction of a New Assay and Altered Specimen‐Processing ProceduresClinical Infectious Diseases, 2008
- Comparative Evaluation of the Automated Roche TaqMan Real-Time Quantitative Human Immunodeficiency Virus Type 1 RNA PCR Assay and the Roche AMPLICOR Version 1.5 Conventional PCR AssayJournal of Clinical Microbiology, 2007
- Human Immunodeficiency Virus Type 1 (HIV-1) Plasma Load Discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 AssaysJournal of Clinical Microbiology, 2007
- Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNAJournal of Clinical Microbiology, 2007