High-viscosity polymethylmethacrylate cement for endoscopic anterior cranial base reconstruction
Authors:
- 1 November 2010
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 113 (5) , 1100-1105
Abstract
Endoscopic endonasal transsphenoidal surgery (ETSS) is an effective, minimally invasive approach for the resection of anterior skull base tumors. Cerebrospinal leakage is a common complication, and repair of the anterior skull base defect with alloplastic materials has been used to minimize the risk of postoperative CSF rhinorrhea and meningitis. Injectable cements, such as low-viscosity polymethylmethacrylate (PMMA), are useful for cranial base reconstruction because they are easy to shape to the contour of the defect. These low-viscosity materials, however, are more susceptible to leakage into the nasal cavity prohibiting their use and are prone to cracking upon hardening. Cement extravasation not only obstructs the operator's view during placement, but it is also associated with significant local and systemic complications. High-viscosity (HV) PMMA-based cement and its specialized delivery system have recently been shown to be safe and effective in human applications. Moreover, its constant high viscosity significantly reduces cement leakage and its associated complications. The authors hypothesized that this type of cement would therefore be ideal for ETSS to repair anterior skull base defects. The authors report their experience using HV-PMMA to reconstruct the anterior skull base in 12 patients following ETSS. The unique puttylike consistency of this material is easy to work, malleable, does not leak into the nasal cavity, does not aspirate into suction tubing, and hardens without cracks in less than 10 minutes. None of the 12 patients suffered postoperative CSF leaks or infections more than 8 months, on average, after surgery. Although not necessary in all cases of ETSS, the authors conclude that HV-PMMA, if needed, may be an excellent choice for reconstructing the anterior skull base after ETSS. Further studies are needed to better assess the long-term outcomes of HV-PMMA cement and its use in repairing skull base defects after extended ETSS.Keywords
This publication has 23 references indexed in Scilit:
- Antibiotic-Impregnated Polymethylmethacrylate Beads and Cement in the Treatment of Posttraumatic Infections of the Frontal SinusPlastic and Reconstructive Surgery, 2009
- Endoscopic Endonasal Transsphenoidal Surgery using a Skull Reference Array and Laser Surface Scanningmin - Minimally Invasive Neurosurgery, 2008
- Percutaneous Vertebroplasty and Bone Cement Leakage: Clinical Experience with a New High-Viscosity Bone Cement and Delivery System for Vertebral Augmentation in Benign and Malignant Compression FracturesCardioVascular and Interventional Radiology, 2008
- High-Viscosity Cement Significantly Enhances Uniformity of Cement Filling in Vertebroplasty: An Experimental Model and Study on Cement LeakageSpine, 2006
- Endoscopic transnasal intradural repair of anterior skull base cerebrospinal fluid fistulaeJournal of Clinical Neuroscience, 2004
- Biomaterials in craniofacial reconstructionClinics in Plastic Surgery, 2004
- Pituitary Surgery: Transsphenoidal ApproachNeurosurgery, 2002
- Size-adjustable titanium plate for reconstruction of the sella turcicaJournal of Neurosurgery, 1999
- Closure of Cerebrospinal Fluid Leakage after Transsphenoidal SurgeryNeurosurgery, 1994
- A new technique for closure of the dura following transsphenoidal and transclival operationsJournal of Neurosurgery, 1990