Development of SPR biosensor for simultaneous detection of multiplex respiratory viruses
Authors:
Open Access
- 1 February 2015
- journal article
- research article
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 26 (1_suppl) , S2207-S2216
Abstract
A surface plasmon resonance (SPR)-based biosensor was developed for specific detection of nine common respiratory virus, including influenza A and influenza B, H1N1, respiratory syncytial virus (RSV), parainfluenza virus 1-3 (PIV1, 2, 3), adenovirus, and severe acute respiratory syndrome coronavirus (SARS). The SPR biosensor was developed by immobilizing nine respiratory virus-specific oligonucleotides in an SPR chip. To increase the biosensor sensitivity, biotin was used to label the PCR primer and further amplify the signal by introducing streptavidin after hybridization. Throat swab specimens representing nine common respiratory viruses were tested by the innovative SPR-based biosensor to evaluate the sensitivity, specificity and reproducibility of this method. Results suggest that this biosensor has the potential to simultaneously identify common respiratory viruses.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of the performance of 2 commercial multiplex PCR platforms for detection of respiratory viruses in upper and lower tract respiratory specimensDiagnostic Microbiology and Infectious Disease, 2015
- Comparison of three commercial RT-PCR systems for the detection of respiratory virusesJournal of Clinical Virology, 2014
- Avidity of influenza virus: Model-based identification of adsorption kinetics from surface plasmon resonance experimentsJournal of Chromatography A, 2014
- Surface plasmon resonance sensing of nucleic acids: A reviewAnalytica Chimica Acta, 2013
- Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensorFood Chemistry, 2013
- Virtual quantification of influenza A virus load by real-time RT-PCRJournal of Clinical Virology, 2013
- Early detection of influenza A and B infection in infants and children using conventional and fluorescence-based rapid testingJournal of Clinical Virology, 2012
- Label-free and high-sensitive detection of Salmonella using a surface plasmon resonance DNA-based biosensorJournal of Biotechnology, 2012
- A review on viral biosensors to detect human pathogensAnalytica Chimica Acta, 2010
- NASBATM isothermal enzymatic in vitro nucleic acid amplification optimized for the diagnosis of HIV-1 infectionJournal of Virological Methods, 1991