Three-Dimensional Fluoroscopy-Navigated Percutaneous Screw Fixation of Acetabular Fractures
Authors:
- 1 December 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 28 (12) , 700-706
Abstract
Objective: Anatomic reduction and articular restoration after acetabular fractures occur (Ac-Fxs) are accepted predictors for good function and slow progression of posttraumatic osteoarthritis of the hip. The aim of this study was to retrospectively analyze Ac-Fxs, which were treated with closed reduction and percutaneous (three-dimensional) fluoroscopy-based navigated screw fixation. Design: Level 4, retrospective clinical and radiographic assessment. Setting: Level 1 trauma center. Patients: Twelve patients (male/female: 9/3; mean age: 60 years; range: 16–80 years) with moderately displaced Ac-Fxs were included. Intervention: In enrolled patients, the treatment involved percutaneous three-dimensional fluoroscopy-based navigated lag screw positioning. Closed reduction was achieved by lag screws, or reduction was aided by the insertion of percutaneous Schanz pins. Main Outcome Measurements: The quality of the reduction and screw positions were assessed using intraoperative and postoperative computed tomography scans. Functional outcome was assessed using the Harris hip score, the visual analog scale for pain, and the Tegener activity scale. Results: A total of 22 periacetabular screws were placed (mean: 1.8 ± 1.1 screws/patient, range: 1–5). The mean follow-up was done for 30 (16–72) months. The postoperative reduction was anatomical in all patients, and the mean fracture displacement was significantly reduced (gap: 4.1 ± 1.8 mm to 0.4 ± 0.7 mm/step: 1.4 ± 0.6 mm to 0.2 ± 0.4 mm). No secondary dislocations or malunions/nonunions were found. All screws correctly addressed the fracture morphology and corresponded to preoperative planning. The Harris hip score, the visual analog scale (motion), and Tegener activity scale showed excellent to very good results (92.4 ± 6.8, 1.9 ± 1.3, and 3.8 ± 1.6, respectively). Conclusions: The navigated, percutaneous screw fixation of selected Ac-Fxs is a promising method that allows for closed reduction and fixation while obtaining a very good radiographic and functional outcome. Level of Evidence: Therapeutic Level 4. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 15 references indexed in Scilit:
- Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional techniqueInjury, 2010
- Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigationArchives of orthopaedic and trauma surgery, 2010
- Differences of percutaneous retrograde screw fixation of anterior column acetabular fractures between male and female: A study of 164 virtual three-dimensional modelsInjury, 2009
- Perkutane, 2D-fluoroskopisch navigierte Sakrumverschraubung in RückenlageDer Unfallchirurg, 2007
- Genauigkeit der CT-basierten Navigation von Pedikelschrauben an der Brustwirbels ule im Vergleich zur konventionellen TechnikDer Unfallchirurg, 2004
- Computer assisted orthopaedic and trauma surgeryInjury, 2003
- Navigationsverfahren in der Becken- und AzetabulumchirurgieDer Unfallchirurg, 2002
- Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the actabulumInjury, 2001
- Percutaneous Fixation of the Columns of the Acetabulum: A New TechniqueJournal of Orthopaedic Trauma, 1998