Determination of methamphetamine and amphetamine in abusers' plasma and hair samples with HPLC‐FL
- 16 September 2003
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 17 (7) , 471-476
Abstract
This paper describes highly sensitive HPLC methods for the determination of amphetamine (AP) and methamphetamine (MP) in abusers' plasma and hair samples. AP and MP were derivatized with the fluorescent reagent, DIB‐Cl, to yield a highly fluorescent DIB‐derivatives of AP and MP, which were then analyzed by HPLC with fluorescence detection at excitation and emission wavelengths of 325 and 430 nm, respectively. The separation was achieved on an ODS column with isocratic mobile phases composed of acetoniltrile and citrate buffer (55:45, v/v) for plasma samples and of acetonitrile–methanol–citrate buffer (45:20:37.5, v/v/v) for hair samples. The limits of detection were less than 0.87 ng/mL and 0.12 ng/mg in plasma and hair samples, respectively, for both AP and MP. The methods were then applied to the determination of MP and its metabolite AP in plasma obtained from two cases of illegally ingested MP and in one of the cases' hair received later. Case I was treated with dialysis; samples before and after dialysis were analyzed by the described method. After dialysis for 5 h, the total plasma levels of AP and MP decreased from 720 to 190 ng/mL. For case II, MP and AP levels were monitored for 3 days after digestion. Total plasma levels decreased from 57 ng/mL in the day of digestion to 11 ng/mL after 3 days. In hair samples, AP and MP could also be detected in very low concentrations. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 22 references indexed in Scilit:
- Drugs of abuse in a non‐conventional sample; detection of methamphetamine and its main metabolite, amphetamine in abusers' clothes by HPLC with UV and fluorescence detectionBiomedical Chromatography, 2001
- Quantification of methamphetamine, amphetamine and enantiomers by semi-micro column HPLC with fluorescence detection; applications on abusers' single hair analysesBiomedical Chromatography, 2000
- Achiral and Chiral Quantification of Methamphetamine and Amphetamine in Human Urine by Semi-micro Column High-Performance Liquid Chromatography and Fluorescence DetectionJournal of Forensic Sciences, 2000
- HPLC with fluorescence detection of methamphetamine and amphetamine in segmentally analyzed human hairThe Analyst, 1999
- Simple and sensitive high-performance liquid chromatographic determination of methamphetamines in human urine as derivatives of 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride, a new fluorescence derivatization reagentJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- Enantioselective high-performance liquid chromatography with fluorescence detection of methamphetamine and its metabolites in human urineThe Analyst, 1998
- Simultaneous gas chromatographic determination of methamphetamine, amphetamine and their p-hydroxylated metabolites in plasma and urineJournal of Chromatography B: Biomedical Sciences and Applications, 1997
- Determination of Phenylisothiocyanate Derivatives of Amphetamine and its Analogues in Biological Fluids by HPLC-APCI-MS or DADJournal of Analytical Toxicology, 1997
- Simple Extractive Derivatization of Methamphetamine and its Metabolites in Biological Materials with Extrelut® Columns for their GC-MS Determination*Journal of Analytical Toxicology, 1997
- Simultaneous Determination of Methamphetamine and Its Metabolites in the Urine Samples of Abusers by High Performance Liquid Chromatography with Chemiluminescence Detection.Biological and Pharmaceutical Bulletin, 1993