4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry
Authors:
- H PaganettiHPH Paganetti
- H JiangHJH Jiang
- A TrofimovATA Trofimov
- 18 February 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (5) , 983-990
Abstract
When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is complex. Furthermore, it is difficult to study double-dynamic systems, e.g., to investigate the influence of time-dependent beam delivery (i.e., magnetically moving beam spots in proton beam scanning) on the dose deposition in a moving target. We recently introduced the technique of 4D Monte Carlo dose calculation to model continuously changing geometries. In intensity modulated proton therapy, dose is delivered by individual pristine Bragg curves. Dose spots are positioned in the patient by varying magnetic field and beam energy. If the movement of these dose spots occurs during significant respiratory motion, interplay effects can take place. Because of the inhomogeneity of individual subfields, the consequences of motion can be more severe than in conventional proton therapy. We demonstrate how the technique of 4D Monte Carlo can be used to study interplay effects in proton beam scanning. Time-dependent beam delivery to a changing patient geometry is simulated in a single 4D dose calculation. Interplay effects between respiratory motion and beam scanning speed are demonstrated.Keywords
This publication has 27 references indexed in Scilit:
- Adaptation of GEANT4 to Monte Carlo dose calculations based on CT dataMedical Physics, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Has 3-D conformal radiotherapy (3D CRT) improved the local tumour control for stage I non-small cell lung cancer?Radiotherapy and Oncology, 2002
- A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapyPhysics in Medicine & Biology, 2001
- Organ motion and its managementInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Monte Carlo dose calculations for dynamic IMRT treatmentsPhysics in Medicine & Biology, 2001
- Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1999
- Beam scanning for heavy charged particle radiotherapyMedical Physics, 1983
- Spot scanning system for proton radiotherapyMedical Physics, 1980
- Range modulators for protons and heavy ionsNuclear Instruments and Methods, 1975