Prediction of CT Substitutes from MR Images Based on Local Diffeomorphic Mapping for Brain PET Attenuation Correction
Authors:
Open Access
- 26 May 2016
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 57 (10) , 1635-1641
Abstract
Attenuation correction is important for PET (positron emission tomography) reconstruction. In PET/MR (magnetic resonance), MR intensities are not directly related to attenuation coefficients that are needed in PET imaging. The attenuation coefficient map can be derived from CT (computed tomography) images. Therefore, prediction of CT substitutes from MR images is desired for attenuation correction in PET/MR. Methods: This study presents a patch-based method for CT prediction from MR images, generating attenuation maps for PET reconstruction. Since no global relation exists between MR and CT intensities, we propose local diffeomorphic mapping (LDM) for CT prediction. In LDM, we assume that MR and CT patches are located on two nonlinear manifolds and the mapping from the MR manifold to the CT manifold approximates a diffeomorphism under a local constraint. Locality is important in LDM and is constrained by the following techniques. First is local dictionary construction, wherein, for each patch in the testing MR image, a local search window is used to extract patches from training MR/CT pairs to construct MR and CT dictionaries. The k-nearest neighbors and an outlier detection strategy are then used to constrain the locality in MR and CT dictionaries. Second is local linear representation, wherein, local anchor embedding is used to solve MR dictionary coefficients when representing the MR testing sample. Under these local constraints, dictionary coefficients are linearly transferred from the MR manifold to the CT manifold, and used to combine CT training samples to generate CT predictions. Results: Our dataset contains 13 healthy subjects, each with T1- and T2-weighted MR and CT brain images. This method provides CT predictions with a mean absolute error of 110.1 Hounsfield units, Pearson's linear correlation of 0.82, peak signal-to-noise ratio of 24.81 dB, and Dice in bone regions of 0.84 as compared to real CTs. CT substitute based PET reconstruction has a regression slope of 1.0084 and R2 of 0.9903 compared to real CT based PET. Conclusion: In this method, no image segmentation or accurate registration is required. Our method demonstrates superior performance in CT prediction and PET reconstruction compared to competing methods.Keywords
This publication has 29 references indexed in Scilit:
- MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI SequenceJournal of Nuclear Medicine, 2012
- Patient classification as an outlier detection problem: An application of the One-Class Support Vector MachineNeuroImage, 2011
- A reproducible evaluation of ANTs similarity metric performance in brain image registrationNeuroImage, 2011
- Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain PrototypeJournal of Nuclear Medicine, 2010
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- PatchMatchACM Transactions on Graphics, 2009
- Statistical parametric mapping (SPM)Scholarpedia, 2008
- New variants of a method of MRI scale standardizationIEEE Transactions on Medical Imaging, 2000
- An Introduction to Kernel and Nearest-Neighbor Nonparametric RegressionThe American Statistician, 1992
- Algorithm AS 136: A K-Means Clustering AlgorithmJournal of the Royal Statistical Society Series C: Applied Statistics, 1979