Quality of image of grating target placed in vitreous of isolated pig eyes photographed through different implanted multifocal intraocular lenses
Authors:
Open Access
- 19 May 2011
- journal article
- Published by Wiley in Acta Ophthalmologica
- Vol. 89 (7) , e561-e566
Abstract
Purpose: To determine the quality of the image of a grating target placed in the vitreous of isolated pig eyes and photographed through implanted refractive and diffractive multifocal intraocular lenses (IOL). Methods: Refractive multifocal (NXG1, PY60MV), diffractive multifocal (ZM900, SA60D3) and monofocal (SA60AT, ZA9003) IOL were implanted in the capsular bag of isolated pig eyes. A grating target was placed in the vitreous and photographed through a flat or a wide-field viewing contact lens. The contrast of the grating targets of different spatial frequencies was measured. Results: With the flat corneal contact lens, the gratings appeared clear and not distorted when viewed through the optics of the NXG1 and PY60MV for far vision but were distorted with reduced contrast when viewed through the optical zone for near vision. The images through the diffractive zone of the ZM900 and SA60D3 were more defocused than with the monofocal IOL (p < 0.005). Ghost images oriented centrifugally of the original image were seen with the ZM900 resulting in lower contrast at higher spatial frequencies than with the SA60D3 with less defocused images only in the central area. With the wide-field viewing contact lens, the images were less defocused and the contrast was comparable to both refractive and diffractive multifocal IOL. Conclusion: Both refractive and diffractive multifocal IOL reduced the contrast of the retinal image when viewed through a flat corneal contact lens but less defocused when viewed through a wide-field viewing contact lens.Keywords
This publication has 13 references indexed in Scilit:
- Quality of Image of Grating Target Placed in Model of Human Eye With Corneal Aberrations as Observed Through Multifocal Intraocular LensesAmerican Journal of Ophthalmology, 2011
- Visual function after monocular implantation of apodized diffractive multifocal or single-piece monofocal intraocular lensJournal of Cataract & Refractive Surgery, 2010
- Visual acuity comparison of 2 models of bifocal aspheric intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- One-Year Outcomes with New-Generation Multifocal Intraocular LensesOphthalmology, 2008
- Intraoperative findings during vitreous surgery after implantation of diffractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2008
- Visualization of the Retinal Image in an Eye Model With Spherical and Aspheric, Diffractive, and Refractive Multifocal Intraocular LensesJournal of Refractive Surgery, 2008
- Refractive Lens Exchange: The Quadruple Win and Current PerspectivesJournal of Refractive Surgery, 2007
- Prospective visual evaluation of apodized diffractive intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Visual Performance of AcrySof ReSTOR Apodized Diffractive IOL: A Prospective Comparative TrialAmerican Journal of Ophthalmology, 2006
- Posterior segment visualization problems with multifocal intraocular lensesActa Ophthalmologica Scandinavica, 1996