Dynamic Neutralization of the Lumbar Spine After Microsurgical Decompression in Acquired Lumbar Spinal Stenosis and Segmental Instability
Authors:
- Andreas KalbarczykAKAndreas Kalbarczyk
- Markus WiesliMWMarkus Wiesli
- Hans LandoltHLHans Landolt
- Javier FandinoJFJavier Fandino
- 1 February 2008
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (3) , E66-E72
Abstract
Prospective clinical study. To report the outcome, radiologic findings, and complications in patients undergoing microsurgical radicular decompression and implantation of Dynesys (Zimmer Spine, Münsingen, Switzerland). The currently available peer-reviewed English-language medical literature addressing the use of the dynamic stabilization systems is limited. Indications, clinical results, and implant failure of Dynesys after microsurgical decompression are still controversial. This study included a total of 37 consecutive patients (mean age 58 years) presenting with acquired lumbar stenosis, signs of segmental instability, and degenerative disc disease underwent lumbar microsurgical decompression and implantation of Dynesys in 1 (n = 11), 2 (n = 17), 3 (n = 9), and 4 segments (n = 1). One patient was lost to follow-up. Lumbar and radicular pain was present in 33 patients (92%). Clinical evaluation included visual analogue scale (leg and back), distribution and severity of pain (%), Prolo Functional and Economic Status, Stauffer Coventry Scale, patient's self evaluation, and radiologic assessment preoperative and postoperative at 3 and 12 months. Leg and back pain (visual analogue scale) improved at 12 months from 8.4 +/- 2.1 to 3.1 +/- 1.4 and from 6.7 +/- 2.8 to 4 +/- 2.8, respectively. Overall pain severity improved due to reduction of radicular pain from 59.2% to 27.3% after microsurgical decompression. Meanwhile, lumbar pain deteriorated from 40.8% to 47.8%. Twenty-seven percent (patient's self-evaluation) and 29.7% (Stauffer Coventry Scale) of the patients described a fair or poor outcome. Moreover, 51% and 54% of the patients had a Prolo Economic Status and Prolo Functional of 4 or 5, respectively. Complications included 4 broken and 2 misplaced screws from a total of 224 screws implanted, 2 loosen systems, and 1 cerebrospinal fistula. At 1-year, a total of 7 patients (19%) required surgical revision. The reported biomechanical principles of Dynesys do not reflect advantages in outcome compared with none or others stabilization systems after microsurgical radicular decompression reported in the literature.Keywords
This publication has 29 references indexed in Scilit:
- The Dynesys Lumbar Spinal Stabilization SystemSpine, 2007
- Dynamic Stabilization in Addition to Decompression for Lumbar Spinal Stenosis with Degenerative SpondylolisthesisSpine, 2006
- Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro studyEuropean Spine Journal, 2005
- Degenerative SpondylolisthesisSpine, 2005
- The Surgical Treatment of the Lumbar Disc ProlapseSpine, 2005
- Long-Term Outcomes of Standard Discectomy for Lumbar Disc HerniationSpine, 2001
- Long-term surgical outcome in 16 patients with thyrotropin pituitary adenomaJournal of Neurosurgery, 2000
- 1997 Volvo Award Winner in Clinical StudiesSpine, 1997
- Treatment of lumbar spinal stenosis by extensive unilateral decompression and contralateral autologous bone fusion: operative technique and resultsJournal of Neurosurgery, 1996
- Radiographic studies of lateral flexion in the lumbar spineJournal of Biomechanics, 1978