Calibrated automated thrombogram II: removing barriers for thrombin generation measurements
Authors:
Open Access
- 28 August 2021
- journal article
- research article
- Published by Springer Nature in Thrombosis Journal
- Vol. 19 (1) , 1-11
Abstract
Background: Thrombin generation (TG) assessed by Calibrated Automated Thrombogram (CAT-I) reflects the overall capacity of plasma to generate thrombin, thus evaluating the balance between the anti- and procoagulant processes. However, with this method the calibrator curve is usually not measured until completion which has a severe impact on the calculation of the TG parameters, especially under conditions where almost all substrate is consumed. In addition, direct thrombin inhibitor (DTI) cannot be present in the calibration sample due to inhibition of the calibrator. We have developed a modified TG assay (CAT-II) and performed head-to-head comparison with the CAT-I method using the same fluorometer. Furthermore, we have compared our CAT-II method to a new automated TG instrument (ST®-Genesia) using the same calibration method.Methods: TG was assessed with CAT-I and CAT-II using the same fulorometer and with ST®-Genesia in control plasma and plasma containing different anticoagulants (dabigatran, rivaroxaban, apixaban) and plasmas to which common interfering substances, bilirubin, hemoglobin and lipids were added. In CAT-I, calibration was against the same plasma containing calibrator in the presence of fluorogenic substrate (Z-GGR-AMC). In contrast, CAT-II method and ST®-Genesia used a standard concentration of thrombin in buffer and 7-amino-4-methylcoumarin (AMC) in a separate plasma sample for calibration.Results: TG obtained from CAT-I using anticoagulant-free plasmas was lower compared with TG from CAT-II but both methods demonstrated an intra-assay variation less than 5% on all measured parameters. When comparing the two different calibration methods in the presence of different anticoagulants, a high correlation was seen in the presence of rivaroxaban and apixaban (R2 > 0.97), but not with dabigatran, a direct thrombin inhibitor. CAT-II method showed dose-dependent inhibition of TG in the presence of dabigatran, while CAT-I was not able to detect it. Both methods were able to correct for the interfering substances.Conclusions: Our results showed high similarity between the results of CAT-I and CAT-II method when it is applied in control plasmas and plasmas not inhibited with a direct thrombin inhibitor. Furthermore, both the CAT-II method and ST-Genesia using the same calibration method were able to detect the effect of all oral anticoagulants. Taken together, applying a new calibration method is a significant improvement for monitoring patients on direct thrombin inhibitors while not introducing any bias to results obtained on other types of samples.Keywords
This publication has 21 references indexed in Scilit:
- Thrombin Generation Assay and Its Application in the Clinical LaboratoryClinical Chemistry, 2016
- From laboratory to clinical practice: Dabigatran effects on thrombin generation and coagulation in patient samplesThrombosis Research, 2015
- Data management in Thrombin GenerationThrombosis Research, 2013
- Interference in Coagulation Testing: Focus on Spurious Hemolysis, Icterus, and LipemiaSeminars in Thrombosis and Hemostasis, 2012
- Preanalytic variables of thrombin generation: towards a standard procedure and validation of the methodJournal of Thrombosis and Haemostasis, 2012
- The effect of total hip/knee replacement surgery and prophylactic dabigatran on thrombin generation and coagulation parametersThrombosis Research, 2012
- Thrombin generation is extremely sensitive to preheating conditionsJournal of Thrombosis and Haemostasis, 2011
- The paradoxical stimulation by a reversible thrombin inhibitor of thrombin generation in plasma measured with thrombinography is caused by α2‐macroglobulin‐thrombinJournal of Thrombosis and Haemostasis, 2010
- Hypercoagulability and thrombotic complications in hemolytic anemiasHaematologica, 2009
- During coagulation, thrombin generation shifts from chemical to diffusional controlJournal of Thrombosis and Haemostasis, 2005