Pentacam anterior chamber parameters in young and middle‐aged Chinese
- 1 January 2013
- journal article
- research article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 96 (1) , 85-91
Abstract
Background The aim was to compare the anterior segment of two groups of Chinese using the Pentacam system. Methods Fifty young (median age 21?years) and 50 middle-aged (median age 46?years) subjects with equal numbers of males and females had their axial length measured with the IOL Master. Their axial anterior chamber depth, anterior chamber volume and temporal and nasal anterior chamber angles were measured using the Pentacam and comparisons were made between the two groups. Results Both groups shared similar axial lengths (unpaired t-test: p = 0.37) but young subjects had significantly deeper anterior chamber by 11 per cent (3.60 +/- 0.40?mm) compared with middle-aged subjects (3.24 +/- 0.34?mm) (analysis of variance: p < 0.001). The anterior chamber volume was significantly greater in young subjects by 24 per cent (200.12 +/- 35.59?mm3) than the middle-aged subjects (161.03 +/- 37.79?mm3). The associations of anterior chamber depth and anterior chamber volume with axial length were significant (R2 from 0.16 to 0.50) and similar in both groups. Young subjects had wider anterior chamber angles (mean differences: 4.60 degrees and 6.07 degrees at temporal and nasal, respectively) than middle-aged subjects. Among middle-aged subjects, females had significantly shorter axial length but anterior chamber depths were similar between the two sexes. Females had significantly smaller anterior chamber volumes. Conclusions Middle-aged subjects had more crowded anterior chambers than young subjects with similar axial lengths. Anterior chamber volume may be a more sensitive parameter to reveal this difference than a linear measurement of the anterior chamber depth.School of OptometrKeywords
This publication has 37 references indexed in Scilit:
- Anterior chamber angle imaging with optical coherence tomographyEye, 2011
- Anterior chamber volume measurements with Visante optical coherence tomography and Pentacam: repeatability and level of agreementClinical & Experimental Ophthalmology, 2009
- High Prevalence of Narrow Angles Among Chinese-American Glaucoma and Glaucoma Suspect PatientsJournal of Glaucoma, 2009
- Potential of the Pentacam in Screening for Primary Angle Closure and Primary Angle Closure SuspectJournal of Glaucoma, 2009
- Quantitative Assessment of Anterior Chamber Volume using Slit-Lamp OCT and PentacamEuropean Journal of Ophthalmology, 2009
- Anterior Chamber Depth in Elderly ChineseOphthalmology, 2008
- Comparison of Gonioscopy and Anterior Segment Ocular Coherence Tomography in Detecting Angle Closure in Different Quadrants of the Anterior Chamber AngleOphthalmology, 2008
- Agreement Between Gonioscopy and Ultrasound Biomicroscopy in Detecting Iridotrabecular AppositionArchives of Ophthalmology (1950), 2007
- Comparison Between Newly Developed Scanning Peripheral Anterior Chamber Depth Analyzer and Conventional Methods of Evaluating Anterior Chamber ConfigurationJournal of Glaucoma, 2006
- Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopyIndian Journal Of Ophthalmology, 2006