Improvement of flux-weakening control of surface mounted permanent magnet synchronous machine considering inverter nonlinearity
Author:
- 1 March 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
This paper proposes the flux-weakening control of the surface mounted permanent magnet synchronous machine in which the voltage losses, for example, inverter nonlinearity and winding resistance voltage drop are considered. In the constant-torque region, to achieve the maximum torque, the d-axis and q-axis currents are controlled tracking the maximum torque per ampere (MTPA) trajectory, while those currents are modified in the flux-weakening region. The proposed method exhibits a good weakening current response because the requirement of d-axis current can be significantly reduced in the infinite constant power speed range compared to the conventional method, which voltage losses are not considered. Accordingly, the efficiency and power factor in the flux-weakening region can be improved. The effectiveness of the proposed method is proved by simulation results.Keywords
This publication has 5 references indexed in Scilit:
- Voltage Control Technique for the Extension of DC-Link Voltage Utilization of Finite-Speed SPMSM DrivesIEEE Transactions on Industrial Electronics, 2011
- Flux-Weakening Control of Nonsalient Pole PMSM Having Large Winding Inductance, Accounting for Resistive Voltage Drop and Inverter NonlinearitiesIEEE Transactions on Power Electronics, 2011
- Closed-loop flux-weakening for permanent magnet synchronous motors2008
- Nonlinearity estimation and compensation of PWM VSI for PMSM under resistance and flux linkage uncertaintyIEEE Transactions on Control Systems Technology, 2006
- Expansion of operating limits for permanent magnet motor by current vector control considering inverter capacityIEEE Transactions on Industry Applications, 1990