Effects of high-temperature heat treatment on Nd3+-doped optical fibers for use in fluorescence intensity ratio based temperature sensing
- 1 July 2003
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 74 (7) , 3524-3530
Abstract
The effect of very high-temperature exposure on the measurementproperties of a fluorescence intensity ratio based optical fiber temperature sensor, using Nd 3+ -doped fiber as the sensing material, has been investigated. The results obtained indicate that exposing the sensormaterial to 750 °C for 100 h improves the accuracy of the fluorescence intensity ratio versus temperature characteristics from approximately 2.5 to approximately 1.3 °C. Measurements of the refractive index profiles of Nd 3+ -doped fiber samples prior to and after exposure to 750 °C indicate that such exposure results in small but measurable changes in the refractive index profile.Keywords
This publication has 16 references indexed in Scilit:
- Fluorescence properties of Er3+ ions in glass ceramics containing LaF3 nanocrystalsOptical Materials, 2002
- Erbium/ytterbium fluorescence based fiber optic temperature sensor systemReview of Scientific Instruments, 2000
- Thulium-doped fiber optic decay-time temperature sensors: Characterization of high temperature performanceReview of Scientific Instruments, 2000
- Nd 3+ -doped optical fiber temperature sensor using the fluorescence intensity ratio techniqueReview of Scientific Instruments, 1999
- A zirconia single-crystal fibre-optic sensor for contact measurement of temperatures above 2000 °CMeasurement Science and Technology, 1999
- Ytterbium-based fluorescence decay time fiber optic temperature sensor systemsReview of Scientific Instruments, 1998
- Spectral characteristics and effects of heat treatment on intrinsic Nd-doped fiber thermometer probesReview of Scientific Instruments, 1998
- Remote thermometry with thermographic phosphors: Instrumentation and applicationsReview of Scientific Instruments, 1997
- Fiber-optic temperature sensor based on internally generated thermal radiationApplied Optics, 1981
- A novel fibre-optic temperature probeOptical and Quantum Electronics, 1977