Raster-Mode Continuous-Flow Liquid Microjunction Mass Spectrometry Imaging of Proteins in Thin Tissue Sections
Open Access
- 16 May 2017
- journal article
- editorial
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (11) , 5683-5687
Abstract
Mass spectrometry imaging by use of continuous-flow liquid microjunction sampling at discrete locations (array mode) has previously been demonstrated. In this Letter, we demonstrate continuous-flow liquid microjunction mass spectrometry imaging of proteins from thin tissue sections in raster mode and discuss advantages (a 10-fold reduction in analysis time) and challenges (suitable solvent systems, data interpretation) of the approach. Visualization of data is nontrivial, requiring correlation of solvent-flow, mass spectral data acquisition rate, data quality, and liquid microjunction sampling area. The latter is particularly important for determining optimum pixel size. The minimum achievable pixel size is related to the scan time of the instrument used. Here we show a minimum achievable pixel size of 50 μm (x-dimension) when using an Orbitrap Elite; however a pixel size of 600 μm is recommended in order to minimize the effects of oversampling on image accuracy.Keywords
Funding Information
- AstraZeneca
- Engineering and Physical Sciences Research Council (EP/F50053X/1, EP/L023490/1)
- National Physical Laboratory, United Kingdom (119375)
This publication has 28 references indexed in Scilit:
- Liquid Extraction Surface Analysis Mass Spectrometry Coupled with Field Asymmetric Waveform Ion Mobility Spectrometry for Analysis of Intact Proteins from Biological SubstratesAnalytical Chemistry, 2015
- Native Liquid Extraction Surface Analysis Mass Spectrometry: Analysis of Noncovalent Protein Complexes Directly from Dried SubstratesJournal of the American Society for Mass Spectrometry, 2015
- Top-Down and Bottom-Up Identification of Proteins by Liquid Extraction Surface Analysis Mass Spectrometry of Healthy and Diseased Human Liver TissueJournal of the American Society for Mass Spectrometry, 2014
- Mass Spectrometry Imaging of Cassette-Dosed Drugs for Higher Throughput Pharmacokinetic and Biodistribution AnalysisAnalytical Chemistry, 2014
- Formal Lithium Fixation Improves Direct Analysis of Lipids in Tissue by Mass SpectrometryAnalytical Chemistry, 2013
- Automated surface sampling of lipids from worn contact lenses coupled with tandem mass spectrometryThe Analyst, 2013
- Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin VariantsJournal of the American Society for Mass Spectrometry, 2012
- Liquid extraction surface analysis mass spectrometry (LESA‐MS) as a novel profiling tool for drug distribution and metabolism analysis: the terfenadine exampleRapid Communications in Mass Spectrometry, 2011
- Hemoglobin Variant Analysis via Direct Surface Sampling of Dried Blood Spots Coupled with High-Resolution Mass SpectrometryAnalytical Chemistry, 2011
- Fully automated liquid extraction‐based surface sampling and ionization using a chip‐based robotic nanoelectrospray platformJournal of Mass Spectrometry, 2009