Using machine learning to predict gamma passing rate in volumetric‐modulated arc therapy treatment plans
Open Access
- 9 December 2022
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (2)
Abstract
Purpose: This study aims to develop an algorithm to predict gamma passing rate (GPR) in the volumetric‐modulated arc therapy (VMAT) technique.Materials and methods: A total of 118 clinical VMAT plans, including 28 mediastina, 25 head and neck, 40 brains intensity‐modulated radiosurgery, and 25 prostate cases, were created in RayStation treatment planning system for Edge and TrueBeam linacs. In‐house scripts were developed to compute Modulation indices such as plan‐averaged beam area (PA), plan‐averaged beam irregularity (PI), total monitor unit (MU), leaf travel/arc length, mean dose rate variation, and mean gantry speed variation. Pretreatment verifications were performed on ArcCHECK phantom with SNC software. GPR was calculated with 3%/2 mm and 10% threshold. The dataset was randomly split into a training (70%) and a test (30%) dataset. A random forest regression (RFR) model and support vector regression (SVR) with linear kernel were trained to predict GPR using the complexity metrics as input. The prediction performance was evaluated by calculating the mean absolute error (MAE), R2, and root mean square error (RMSE).Results: RMSEs at γ 3%/2 mm for RFR and SVR were 1.407 ± 0.103 and 1.447 ± 0.121, respectively. MAE was 1.14 ± 0.084 for RFR and 1.101 ± 0.09 for SVR. R2 was equal to 0.703 ± 0.027 and 0.689 ± 0.053 for RFR and SVR, respectively. GPR of 3%/2 mm with a 10% threshold can be predicted with an error smaller than 3% for 94% of plans using RFR and SVR models. The most important metrics that had the greatest impact on how accurately GPR can be predicted were determined to be the PA, PI, and total MU.Conclusion: In terms of its prediction values and errors, SVR (linear) appeared to be comparable with RFR for this dataset. Based on our results, the PA, PI, and total MU calculations may be useful in guiding VMAT plan evaluation and ultimately reducing uncertainties in planning and radiation delivery.Keywords
This publication has 36 references indexed in Scilit:
- Survival Prediction and Feature Selection in Patients with Breast Cancer Using Support Vector RegressionComputational and Mathematical Methods in Medicine, 2016
- Quantification of beam complexity in intensity‐modulated radiation therapy treatment plansMedical Physics, 2014
- Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapyMedical Physics, 2013
- Catching errors with patient-specific pretreatment machine log file analysisPractical Radiation Oncology, 2013
- Penalization of aperture complexity in inversely planned volumetric modulated arc therapyMedical Physics, 2012
- Statistical variability and confidence intervals for planar dose QA pass ratesMedical Physics, 2011
- Verification of monitor unit calculations for non‐IMRT clinical radiotherapy: Report of AAPM Task Group 114Medical Physics, 2010
- A new metric for assessing IMRT modulation complexity and plan deliverabilityMedical Physics, 2010
- Predicting respiratory tumor motion with multi-dimensional adaptive filters and support vector regressionPhysics in Medicine & Biology, 2009
- Random ForestsMachine Learning, 2001