POISED-5, a portable on-board electrochemical impedance spectroscopy biomarker analysis device
Open Access
- 4 July 2019
- journal article
- research article
- Published by Springer Nature in Biomedical Microdevices
- Vol. 21 (3) , 1-14
Abstract
Point-of-care medical devices offer the potential for rapid biomarker detection and reporting of medical conditions, thereby bypassing the requirements for offline clinical laboratory facilities in many cases. Label-free electrochemical techniques are suitable for use in handheld diagnostic devices due the inherent electronic detection modality and low requirement for processing reagents. While electrochemical impedance sensing is widely used in tissue analysis such as body composition measurement, its use in point-of-care patient testing is yet to be widely adopted. Here we have considered a number of issues currently limiting the translation of electrochemical impedance sensing into clinical biosensor devices. Specifically, we have addressed the current requirement for these sensors to be connected to an external processor by applying a minimum number of frequencies required for optimized biomarker detection, and subsequently delivering analytics within the measurement device. The POISED-5 device was evaluated using a sensor for the ovarian cancer biomarker cancer antigen 125 (CA125), demonstrating performance comparable to standard laboratory equipment, with direct interpretation of response signal amplitude substituting traditional impedance component calculation and model fitting.Keywords
Funding Information
- Swansea University
This publication has 62 references indexed in Scilit:
- A Family of New Generation Miniaturized Impedance Analyzers for Technical Object DiagnosticsMetrology and Measurement Systems, 2013
- Development of Galvanostatic Fourier Transform Electrochemical Impedance SpectroscopyAnalytical Chemistry, 2013
- Interface circuit for impedance sensors using two specialized single-chip microsystemsSensors and Actuators A: Physical, 2010
- Handheld impedance biosensor system using engineered proteinaceous receptorsBiomedical Microdevices, 2010
- Electrochemical Impedance SpectroscopyAnnual Review of Analytical Chemistry, 2010
- An integrated approach to electrochemical impedance spectroscopyElectrochimica Acta, 2008
- Label‐Free Impedance Biosensors: Opportunities and ChallengesElectroanalysis, 2007
- Handheld-Impedance-Measurement System With Seven-Decade Capability and Potentiostatic FunctionIEEE Transactions on Instrumentation and Measurement, 2006
- On the Error Structure of Impedance MeasurementsJournal of the Electrochemical Society, 2003
- Analogue and digital lock-in techniques for very-low-frequency impedance spectroscopyMeasurement Science and Technology, 1997