Impact of DFIG‐based wind farm integration on sub‐synchronous torsional interaction between HVDC and thermal generators
Authors:
Open Access
- 21 June 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (17) , 3913-3923
Abstract
In western China, large‐scale wind power is generally bundled with thermal power, and transmitted to eastern China by high‐voltage direct current (HVDC) systems. This constitutes the wind–thermal bundled system transmitted by HVDC (WTBH). In this study, a typical studied system of WTBH is presented, and its models for eigenvalue analysis are introduced. To improve the efficiency of eigenvalue analysis, an improved block modelling method is proposed for building the state‐space model of WTBH. By eigenvalue analysis and electromagnetic transient (EMT) simulation, the impact of doubly‐fed induction generator (DFIG)‐based wind farm integration on sub‐synchronous torsional interaction (SSTI) between thermal generators (TGs) and HVDC was investigated. The sensitivity of the operating parameters of DFIG‐based wind farms was analysed, including wind speed, wind farm scale, and distance between the wind farm and HVDC rectifier station. The obtained results show that the integration of DFIG‐based wind farms can mitigate the SSTI between the TG and HVDC. The system becomes more stable as the wind speed and wind farm scale increase or the distance between the wind farm and HVDC rectifier station decreases. The conclusions of this study are validated through EMT simulations in PSCAD/EMTDC, and provide theoretical reference for practical WTBH projects.Keywords
Funding Information
- National Natural Science Foundation of China (51507064)
This publication has 19 references indexed in Scilit:
- A Comparative Sub-synchronous Resonance Analysis of Grid-connected Doubly Fed Induction Generator Based and Permanent Magnet Synchronous Generator Based Wind FarmsElectric Power Components and Systems, 2015
- Modal Analysis of Induction Generator Based Wind Farm Connected to Series-compensated Transmission Line and Line Commutated Converter High-Voltage DC Transmission LineElectric Power Components and Systems, 2014
- Sub-Synchronous Resonance damping via Doubly Fed Induction GeneratorInternational Journal of Electrical Power & Energy Systems, 2013
- Subsynchronous resonance in single-cage self-excited-induction-generator-based wind farm connected to series-compensated linesIET Generation, Transmission & Distribution, 2011
- Research on SSO Caused by HVDC Based on Eigenvalue AnalysisAdvanced Materials Research, 2011
- Frequency-domain modelling of sub-synchronous torsional interaction of synchronous machines and a high voltage direct current transmission link with line-commutated convertersIET Generation, Transmission & Distribution, 2010
- Aggregated dynamic model for wind farms with doubly fed induction generator wind turbinesRenewable Energy, 2008
- Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generatorIET Generation, Transmission & Distribution, 2007
- The Study of SSTI Between Guizhou-Guangdong II ±500 kV DC Transmission Link and Steam-Turbine-Generators Near the Rectifier Terminal2006
- Reader's guide to subsynchronous resonanceIEEE Transactions on Power Systems, 1992