High Precision 16-bit Readout Gas Sensor Interface in 0.13μm CMOS
- 1 May 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02714302,p. 3071-3074
Abstract
A high precision 16-bit readout circuit for gas sensor interface is realized in 0.13μm CMOS technology. The front end signal conditioning circuit comprises a low power resistance-to-time period converter with subthreshold operation of transistors. The time-period proportional to the transducer output is digitized using a counter based frequency-to-digital conversion (FDC) technique. In order to handle the sensor signal with a dynamic range of 160dB, subranging technique is employed to provide feedback to front end circuit interfacing the sensor. While the 3 MSBs of 16-bit word restrict the input frequency to FDC between 1MHz and 10MHz, the 13-bit counter operates on this signal to provide a worst case resolution of 0.4%. The power consumption of the readout circuit is 366μW from a 1.2V supply.Keywords
This publication has 8 references indexed in Scilit:
- A complete front-end system read-out and temperature control for resistive gas sensor array2006
- Flexible High-Accuracy Wide-Range Gas Sensor Interface for Portable Environmental Nosing Purpose2005
- A time-to-digital-converter-based CMOS smart temperature sensorIEEE Journal of Solid-State Circuits, 2005
- A high-precision time-to-digital converter using a two-level conversion schemeIEEE Transactions on Nuclear Science, 2004
- Hotplate-based monolithic CMOS microsystems for gas detection and material characterization for operating temperatures up to 500/spl deg/CIEEE Journal of Solid-State Circuits, 2004
- An 11-bit High-Resolution and Adjustable-Range CMOS Time-to-Digital Converter for Space Science InstrumentsIEEE Journal of Solid-State Circuits, 2004
- Time-to-digital conversion with 10 ps single shot resolution2002
- An integrated time-to-digital converter with 30-ps single-shot precisionIEEE Journal of Solid-State Circuits, 2000