Delayed endothelialization of watchman device identified with cardiac CT
- 30 June 2019
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 30 (8) , 1319-1324
Abstract
Background: Left atrial appendage (LAA) closure with the Watchman device is increasingly used in patients with nonvalvular atrial fibrillation for stroke prevention. Though clinical trials have shown a similar combined risk of ischemic and hemorrhagic stroke, there is an increased risk of ischemic stroke in patients with a Watchman device compared with anticoagulation. Some ischemic strokes are related to a device‐related thrombus (DRT), which may be attributable to delayed endothelialization of exposed fabric and metal.Methods and Results: Patients undergoing Watchman LAA occlusion between January 2016 and June 2018 were enrolled in a prospective registry. From this cohort, 46 patients who had both transesophageal echocardiogram (TEE) and computed tomography (CT) at 45 days follow‐up were selected for this study. The degree of LAA occlusion and type of leak were assessed by CT and TEE. TEE identified no patients with a significant (>5 mm) peri‐device leak, 27 (58.6%) with nonsignificant peri‐device leak (<5 mm), and 19 (41.4%) with complete occlusion. CT identified contrast in the LAA in 28 (60%) patients. However, in 10 (21.8%) of these patients, contrast entered the LAA through the fabric rather than around the device. No DRT were identified.Conclusion: These data reveal that the Watchman device remains porous 6 weeks after implantation in a substantial percentage of patients, suggesting delayed endothelialization of the device. Cardiac CT may help to differentiate between peri‐device and trans‐fabric leak. Additional studies are required to test whether prolonged anticoagulation in patients with trans‐fabric leak may help to reduce the risk of DRT and ischemic stroke.Keywords
Funding Information
- Roz and Marvin H Weiner and Family Foundation
- Dresher Foundation
- Dr. Francis P. Chiaramonte Foundation
- Marilyn and Christian Poindexter Arrhythmia Research Fund
- Mr. and Mrs. Larry Small AF Research Fund
- Norbert and Louise Grunwald Cardiac Arrhythmia Research Fund
- Edward St. John Fund for AF Research
This publication has 12 references indexed in Scilit:
- Device-Related Thrombus After Left Atrial Appendage ClosureCirculation, 2018
- Incidence, Characteristics, and Clinical Course of Device-Related Thrombus After Watchman Left Atrial Appendage Occlusion Device Implantation in Atrial Fibrillation PatientsJACC: Clinical Electrophysiology, 2017
- Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registryEuropean Heart Journal, 2016
- Cardiac CT angiography for device surveillance after endovascular left atrial appendage closureEuropean Heart Journal - Cardiovascular Imaging, 2015
- Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin TherapyJACC, 2014
- Estimates of Current and Future Incidence and Prevalence of Atrial Fibrillation in the U.S. Adult PopulationThe American Journal of Cardiology, 2013
- Guidelines for Performing a Comprehensive Transesophageal Echocardiographic Examination: Recommendations from the American Society of Echocardiography and the Society of Cardiovascular AnesthesiologistsJournal of the American Society of Echocardiography, 2013
- Incomplete Endothelialization of Left Atrial Appendage Occlusion Device 10 Months After ImplantationJournal of Cardiovascular Electrophysiology, 2012
- Left Atrial Appendage ObliterationJACC: Cardiovascular Interventions, 2010
- Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trialThe Lancet, 2009