Seismic Behavior of a Masonry Chimney with Severe Cracking Condition: Preliminary Study
- 1 August 2014
- journal article
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 628, 117-122
Abstract
This paper presents a structural analysis of a masonry chimney built in the 1940s, which is currently being cataloged as local interest heritage. This structure has not served any industrial purpose for the last thirty years. The chimney is located in the town of Agost (Alicante - Spain) and directly exposed to the prevailing winds from the sea, as it is approximately 12 km away from the waterfront and there are not any significant barriers, which could protect the structure against the wind. There are longitudinal cracks and fissures all along the shaft because of the chimney’s geometrical characteristics, the effect of the masonry creep and especially the lack of maintenance. Moreover, there is also a permanent bending deformation in the upper 1/3 of the height due to the wind pressure. A numerical analysis for the static behavior against gravity and wind loads was performed using the structure’s current conditions after a detailed report of its geometry, its construction system and the cracking pattern. Afterwards, the dynamic behavior was studied, i.e. a seismic analysis using both response spectra and accelerograms in order to examine the structural stability. This work shows the pre-monitoring analysis before any experimental testing. Using the current results the future test conditions will be determined (e.g. number of sensors and monitoring point location, excitation systems, etc) prior to a possible structural reinforcement by applying composite material (fiber reinforced polymers).Keywords
This publication has 10 references indexed in Scilit:
- Comparative analysis on the seismic behaviour of unreinforced masonry buildings with flexible diaphragmsEngineering Structures, 2014
- Seismic vulnerability assessment of historical masonry structural systemsEngineering Structures, 2014
- Eurocode 8: Design of structures for earthquake resistance2013
- Eurocode 6. Design of masonry structures2013
- Seismic capacity evaluation of unreinforced masonry residential buildings in AlbaniaNatural Hazards and Earth System Sciences, 2012
- State of the art of industrial masonry chimneys: A review from construction to strengtheningConstruction and Building Materials, 2011
- Seasonally frozen soil's effect on stochastic response of masonry minaret–soil interaction systems to random seismic excitationCold Regions Science and Technology, 2010
- Influence of experimental data and FE model on updating results of a brick chimneyAdvances in Engineering Software, 2008
- Recommendations for restoration of ancient buildings and the survival of a masonry chimneyConstruction and Building Materials, 2006
- Seismic behaviour of industrial masonry chimneysInternational Journal of Solids and Structures, 2006