Ronchi-Calibrated Bidirectional Fast Volume-Repeat OCT for High-Speed 4D Imaging
Authors:
- Yaping ShiYSYaping Shi
- Zhaoyu GongZGZhaoyu Gong
- Zhaodong LuZLZhaodong Lu
- Zhuoqun YuanZYZhuoqun Yuan
- Muyun HuMHMuyun Hu
- Yi ZhangYZYi Zhang
- Ruikang WangRWRuikang Wang
- 24 June 2026
- journal article
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (14) , 4036
Abstract
We present a bidirectional scanning and distortion correction framework for high-speed, wide-field 4D SS-OCT imaging. Forward and backward scans are combined to improve acquisition efficiency, while a Ronchi-based calibration is introduced to correct direction-dependent geometric distortion at high frame rates. Stripe boundary features are extracted to establish calibration markers, and a polynomial model is employed to map nonlinear sampling coordinates to true spatial positions. The resulting distortion maps enable remapping to a common linear grid with consistent spatial sampling. This approach increases the acquisition duty cycle by 50%, achieving volumetric imaging rates of 15 Hz over an expanded lateral field of view of 4 × 4 mm 2 . We demonstrate the capability of the proposed method in trabecular meshwork dynamics imaging with reduced phase-wrapping artifacts resulting from inter-volume motion. This method enables practical high-speed, wide-field 4D functional OCT imaging.Keywords
Funding Information
- Kren Engineering-based Medicine Initiative
- Washington Research Foundation
This publication has 9 references indexed in Scilit:
- Volumetric imaging of trabecular meshwork dynamic motion using 600 kHz swept source optical coherence tomographyBiomedical Optics Express, 2024
- Light-adapted flicker-optoretinography based on raster-scan optical coherence tomography towards clinical translationBiomedical Optics Express, 2024
- High-speed, long-range and wide-field OCT for in vivo 3D imaging of the oral cavity achieved by a 600 kHz swept source laserBiomedical Optics Express, 2024
- Scan multiplier unit for ultrafast laser scanning beyond the inertia limitOptica, 2021
- Development of a clinical prototype of a miniature hand-held optical coherence tomography probe for prematurity and pediatric ophthalmic imagingBiomedical Optics Express, 2019
- Effective bidirectional scanning pattern for optical coherence tomography angiographyBiomedical Optics Express, 2018
- Optimization of galvanometer scanning for optical coherence tomographyApplied Optics, 2015
- Experimental investigations of the scanning functions of galvanometer-based scanners with applications in OCTApplied Optics, 2011
- A practical approach to eliminate autocorrelation artefacts for volume-rate spectral domain optical coherence tomographyPhysics in Medicine & Biology, 2006