Performance Assessment for the Validation of Wireless Communication Engines in an Innovative Wearable Monitoring Platform
Open Access
Abstract
In today’s health-monitoring applications, there is a growing demand for wireless and wearable acquisition platforms capable of simultaneously gathering multiple bio-signals from multiple body areas. These systems require well-structured software architectures, both to keep different wireless sensing nodes synchronized each other and to flush collected data towards an external gateway. This paper presents a quantitative analysis aimed at validating both the wireless synchronization task (implemented with a custom protocol) and the data transmission task (implemented with the BLE protocol) in a prototype wearable monitoring platform. We evaluated seven frequencies for exchanging synchronization packets (10 Hz, 20 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 70 Hz) as well as two different BLE configurations (with and without the implementation of a dynamic adaptation of the BLE Connection Interval parameter). Additionally, we tested BLE data transmission performance in five different use case scenarios. As a result, we achieved the optimal performance in the synchronization task (1.18 ticks as median synchronization delay with a Min-Max range of 1.60 ticks and an Interquartile range (IQR) of 0.42 ticks) when exploiting a synchronization frequency of 40 Hz and the dynamic adaptation of the Connection Interval. Moreover, BLE data transmission proved to be significantly more efficient with shorter distances between the communicating nodes, growing worse by 30.5% beyond 8 m. In summary, this study suggests the best-performing network configurations to enhance the synchronization task of the prototype platform under analysis, as well as quantitative details on the best placement of data collectors.Keywords
This publication has 11 references indexed in Scilit:
- Data Quality Assessment for the Validation of Synchronization Performance in an Innovative Wireless Multi-Node Monitoring Platform2023
- Feasibility study of an embedded platform for biopotentials acquisition during sports activities2022
- Biopotential Signal Monitoring Systems in Rehabilitation: A ReviewSensors, 2021
- Principles of Construction, Structure and Features of the ECG and Blood Pressure Monitoring System2020
- Performance evaluation of time synchronization using current consumption pattern of BLE devices2018
- Performance Evaluation of Bluetooth Low Energy: A Systematic ReviewSensors, 2017
- Energy Analysis of Device Discovery for Bluetooth Low Energy2013
- Overview and Evaluation of Bluetooth Low Energy: An Emerging Low-Power Wireless TechnologySensors, 2012
- A low-power, wireless, 8-channel EEG monitoring headset2010
- Handbook of Sensor Networks2005