A Surgical Robotic System for Long-Bone Fracture Alignment: Prototyping and Cadaver Study
- 19 November 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (1) , 172-182
Abstract
In this paper, we design, develop, and validate a surgical robotic system, entitled Robossis, to assist long-bone fracture reduction, i.e., alignment, surgeries. Unlike traditional long-bone fracture surgeries, Robossis enables the surgeon to precisely align the fractured bone in the presence of large traction forces and torques. The proposed surgical system includes a novel 3-armed robot, a bone-gripping mechanism, and a master controller. The 6-DOF 3-armed wide-open parallel robot has a unique architecture, which facilitates positioning the bone inside the robot, providing a large workspace for surgical maneuvers. Kinematic analysis shows that the symmetric 3-armed mechanism provides a significant advantage over the Gough-Stewart platform, i.e., 15 times larger rotational workspace, which is a vital advantage for fracture alignment. Theoretical and experimental testing are performed to demonstrate Robossis performance, including high accuracy and force insertion capabilities. A successful cadaver test was performed using a Robossis prototype, which shows that guided by intraoperative X-ray imaging, Robossis is able to manipulate bone in all translational and rotational directions while encountering the muscle payload surrounding the femur. Robossis is designed to balance accuracy, payload, and workspace, and its innovative design presents major advantages over the existing robot designs for the reduction of long-bone fractures.Keywords
Funding Information
- National Science Foundation (2005570)
- New Jersey Health Foundation (PC 62-21)
This publication has 55 references indexed in Scilit:
- A novel passive/active hybrid robot for orthopaedic trauma surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Novel 3D hexapod computer‐assisted orthopaedic surgery system for closed diaphyseal fracture reductionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2011
- Trends in subtrochanteric, diaphyseal, and distal femur fractures, 1984–2007Osteoporosis International, 2011
- A comparison of cortical bone thickness in the femoral midshaft of humans and two non-human mammalsHOMO, 2009
- A rat model for evaluating physiological responses to femoral shaft fracture reduction using a surgical robotJournal of Orthopaedic Research, 2008
- An estimate of the worldwide prevalence and disability associated with osteoporotic fracturesOsteoporosis International, 2006
- A surgical telemanipulator for femur shaft fracture reductionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- Forces and torques during fracture reduction: Intraoperative measurements in the femurJournal of Orthopaedic Research, 2006
- A hexapod robot external fixator for computer assisted fracture reduction and deformity correctionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2004