Laser Doppler Vibrometry Measures of Physiological Function: Evaluation of Biometric Capabilities
- 10 June 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Forensics and Security
- Vol. 5 (3) , 449-460
Abstract
A novel approach for remotely sensing mechanical cardiovascular activity for use as a biometric marker is proposed. Laser Doppler Vibrometry (LDV) is employed to sense vibrations on the surface of the skin above the carotid artery related to arterial wall movements associated with the central blood pressure pulse. Carotid LDV signals are recorded using noncontact methods and the resulting unobtrusiveness is a major benefit of this technique. Several recognition methods are proposed that use the temporal and/or spectral information in the signal to assess biometric performance both on an intrasession basis, and on an intersession basis where LDV measurements were acquired from the same subjects after delays ranging from one week to six months. A waveform decomposition method that utilizes principal component analysis is used to model the signal in the time domain. Authentication testing for this approach produces an equal-error rate of 0.5% for intrasession testing. However, performance degrades substantially for intersession testing, requiring a more robust approach to modeling. Improved performance is obtained using techniques based on time-frequency decomposition, incorporating a method for extracting informative components. Biometric fusion methods including data fusion and information fusion are applied to train models using data from multiple sessions. As currently implemented, this approach yields an intersession equal-error rate of 6.3%.Keywords
This publication has 36 references indexed in Scilit:
- Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometryThe Journal of Laryngology & Otology, 2009
- eigenPulse: Robust human identification from cardiovascular functionPattern Recognition, 2008
- Analysis of Human Electrocardiogram for Biometric RecognitionEURASIP Journal on Advances in Signal Processing, 2007
- Verification of humans using the electrocardiogramPattern Recognition Letters, 2007
- Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetryReview of Scientific Instruments, 2007
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- ECG to identify individualsPattern Recognition, 2005
- Thresholding method for dimensionality reduction in recognition systemsIEEE Transactions on Information Theory, 2001
- ECG analysis: a new approach in human identificationIEEE Transactions on Instrumentation and Measurement, 2001
- Small sample size effects in statistical pattern recognition: recommendations for practitionersIEEE Transactions on Pattern Analysis and Machine Intelligence, 1991