Geometric uncertainty of 2D projection imaging in monitoring 3D tumor motion
Authors:
- Sonja DieterichSDSonja Dieterich
- Paul J KeallPKPaul J Keall
- 18 May 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (12) , 3439-3454
Abstract
The purpose of this study was to investigate the accuracy of two-dimensional (2D) projection imaging methods in three-dimensional (3D) tumor motion monitoring. Many commercial linear accelerator types have projection imaging capabilities, and tumor motion monitoring is useful for motion inclusive, respiratory gated or tumor tracking strategies. Since 2D projection imaging is limited in its ability to resolve the motion along the imaging beam axis, there is unresolved motion when monitoring 3D tumor motion. From the 3D tumor motion data of 160 treatment fractions for 46 thoracic and abdominal cancer patients, the unresolved motion due to the geometric limitation of 2D projection imaging was calculated as displacement in the imaging beam axis for different beam angles and time intervals. The geometric uncertainty to monitor 3D motion caused by the unresolved motion of 2D imaging was quantified using the root-mean-square (rms) metric. Geometric uncertainty showed interfractional and intrafractional variation. Patient-to-patient variation was much more significant than variation for different time intervals. For the patient cohort studied, as the time intervals increase, the rms, minimum and maximum values of the rms uncertainty show decreasing tendencies for the lung patients but increasing for the liver and retroperitoneal patients, which could be attributed to patient relaxation. Geometric uncertainty was smaller for coplanar treatments than non-coplanar treatments, as superior-inferior (SI) tumor motion, the predominant motion from patient respiration, could be always resolved for coplanar treatments. Overall rms of the rms uncertainty was 0.13 cm for all treatment fractions and 0.18 cm for the treatment fractions whose average breathing peak-trough ranges were more than 0.5 cm. The geometric uncertainty for 2D imaging varies depending on the tumor site, tumor motion range, time interval and beam angle as well as between patients, between fractions and within a fraction.Keywords
This publication has 45 references indexed in Scilit:
- Investigation of patient, tumour and treatment variables affecting residual motion for respiratory-gated radiotherapyPhysics in Medicine & Biology, 2006
- Development of a four-dimensional image-guided radiotherapy system with a gimbaled X-ray headInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Technical aspects of image-guided respiration-gated radiation therapyMedical Dosimetry, 2006
- A technique for respiratory-gated radiotherapy treatment verification with an EPID incinemodePhysics in Medicine & Biology, 2005
- A feasibility study on the prediction of tumour location in the lung from skin motionBritish Journal of Radiology, 2004
- Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectorsPhysics in Medicine & Biology, 2004
- The effects of tumor motion on planning and delivery of respiratory‐gated IMRTMedical Physics, 2003
- Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulationPhysics in Medicine & Biology, 2002
- Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patientsMedical Physics, 2001
- Automatic three‐dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography dataMedical Physics, 1996