Dynamic Change of the Upper Airway during Inhalation via Aerosol Delivery Devices
- 1 December 2004
- journal article
- Published by SAGE Publications in Journal of Aerosol Medicine
- Vol. 17 (4) , 325-334
Abstract
Although it is likely that the upper airway is a major factor in the large inter- and intra-subject variation in deposition of inhaled drug aerosols in the lung, data on the configuration of the upper airway during inhalation is sparse. We have developed a unique method, using magnetic resonance imaging, to reconstruct the upper airway in three dimensions during inhalation from aerosol devices used to deliver medication to patients with asthma, chronic obstructive pulmonary disease, and cystic fibrosis. Ten healthy adults were imaged while inhaling from a pressurized metered dose inhaler (pMDI), a spacer used with pMDI (spacer), and a high-resistance dry powder inhaler, the Turbuhaler (DPI). The mean cross-sectional area of the oropharyngeal region was significantly larger (Wilcoxon's signed-rank test with Bonferroni correction, p < 0.0167) when the DPI (281 [143] mm2, mean [SD]) was used compared to the spacer (205 [32] mm2, p = 0.016) or pMDI (152 [48] mm2, p = 0.013). Considerable variations in the cross-sectional areas of the oral cavity, oropharynx, and larynx were seen when compared to the upper trachea. The main cause for this was the varying position of the tongue during inhalation via the devices. Although differences were observed when comparing the total volume of the upper airway during inhalation via the DPI (70 [17] cm3) to the pMDI (56 [20] cm3, p = 0.037) or spacer (59 [12] cm3, p = 0.022), these did not reach significance. This study shows that there are very significant variations in the configuration of the upper airway when different devices are used for inhalation. These changes are likely to be produced by a number of factors, including tongue position, device airflow resistance, and patient effort.Keywords
This publication has 27 references indexed in Scilit:
- In Vitro Monodisperse Aerosol Deposition in a Mouth and Throat with Six Different Inhalation DevicesJournal of Aerosol Medicine, 2001
- Mouthpiece Diameter Affects Deposition Efficiency in Cast Models of the Human Oral AirwaysJournal of Aerosol Medicine, 2001
- Pulmonary administration of aerosolised fentanyl: pharmacokinetic analysis of systemic deliveryBritish Journal of Clinical Pharmacology, 1998
- Aerosol particle transport and deaggregation phenomena in the mouth and throatAdvanced Drug Delivery Reviews, 1997
- Toward articulatory-acoustic models for liquid approximants based on MRI and EPG data. Part I. The lateralsThe Journal of the Acoustical Society of America, 1997
- On the Use of Computational Fluid Dynamics for Simulating Flow and Particle Deposition in the Human Respiratory TractJournal of Aerosol Medicine, 1996
- A Registration and Interpolation Procedure for Subvoxel Matching of Serially Acquired MR ImagesJournal of Computer Assisted Tomography, 1995
- Deposition of inhaled particles in the mouth and throat of asthmatic subjectsEuropean Respiratory Journal, 1994
- Modelling the deposition of inhaled powdered drug aerosolsJournal of Aerosol Science, 1994
- Mouth and Throat Deposition of 3.6 μm Radiolabelled Particles in AsthmaticsJournal of Aerosol Medicine, 1991