A self‐gating method for time‐resolved imaging of nonuniform motion
Authors:
- 9 October 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 76 (3) , 919-925
Abstract
Purpose: To develop a self‐gating method capable of assessing nonuniform motion, e.g., in cardiovascular magnetic resonance imaging of patients with severe arrhythmia, or for imaging of the temporomandibular joint.Methods: The proposed method allows cyclic motion trajectories with a nonuniform pace by replacing the one‐dimensional gating signal of conventional image‐based self‐gating with a two‐dimensional gating matrix. The resulting image quality is compared with conventional self‐gating and real‐time MRI.Results: Nonuniform self‐gating resulted in superior image quality compared with conventional self‐gating and the feasibility study showed significantly improved image sharpness (P < 0.01). Further, improvements in image quality were shown compared with golden angle radial parallel sparse MRI.Conclusion: A new self‐gating method was proposed that allows cardiovascular magnetic resonance of arrhythmic patients, which is a common problem in clinical practice. Further, the proposed method enables self‐gated imaging of the temporomandibular joint. Magn Reson Med 76:919–925, 2016.Keywords
This publication has 24 references indexed in Scilit:
- Evaluation of left ventricular ejection fraction using through-time radial GRAPPAJournal of Cardiovascular Magnetic Resonance, 2014
- High‐resolution respiratory self‐gated golden angle cardiac MRI: Comparison of self‐gating methods in combination with k‐t SPARSE SENSEMagnetic Resonance in Medicine, 2014
- Dynamic MRI of the TMJ under physical loadDentomaxillofacial Radiology, 2013
- Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolutionJournal of Cardiovascular Magnetic Resonance, 2013
- Nonlinear Dynamics in CardiologyAnnual Review of Biomedical Engineering, 2012
- High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resortingMagnetic Resonance in Medicine, 2009
- Self‐gated cardiac cine MRIMagnetic Resonance in Medicine, 2003
- Wireless retrospective gating: Application to cine cardiac imagingMagnetic Resonance Imaging, 1990
- Dynamic display of the temporomandibular joint meniscus by using "fast-scan" MR imagingAmerican Journal of Roentgenology, 1987
- ECG-synchronized cardiac MR imaging: method and evaluation.Radiology, 1985