A clinical comparison of glycol and water-based heater-cooler systems for cardiopulmonary bypass
- 6 August 2024
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 40 (4) , 947-954
Abstract
Introduction: While newer heater-cooler technologies using ethylene glycol-based (GB) solutions during cardiothoracic surgery have become commercially available, there is a paucity of clinical data describing their effectiveness during cardiopulmonary bypass (CPB) support. This analysis aimed to compare clinical characteristics and procedural outcomes using water-based (WB) and GB heater-cooler systems. Methods: A retrospective analysis was performed on consecutive adult patients undergoing CPB from June to October 2022 comparing WB or GB groups. The primary outcome was a composite of operative death or major morbidity. Secondary endpoints included transfusion requirements on CPB, patient cooling and warming rates, and vasoactive-inotropic scores (VIS) at case completion. P-control charts were used to monitor the weekly incidence of the composite outcome. A sub-analysis was performed to evaluate the primary outcome for cardiac surgery cases indexed by the Society of Thoracic Surgeons (STS). Results: There were 167 patients included for analysis; 87 (52.1%) underwent CPB with a WB system and 80 (47.9%) with a GB system. GB procedure subjects were younger ( p = .01), experienced longer CPB times ( p = .034), and were more likely to receive thoracic transplant or aortic surgery ( p = 0.015). The composite outcome of operative mortality or major morbidity occurred in 29.9% and 24% of the WB and GB groups, respectively ( p = .372). P-control charts indicated a weekly mean incidence of 30% during WB practice, which decreased to 24% with GB practice. Among 106 STS-indexed cardiac surgery cases, mean composite outcome incidence decreased from 19% to 6% following our GB transition. Additionally, cooling, and warming rates indexed to patient BSA and VIS at case completion were not significantly different. Conclusion: Our analysis demonstrated a safe transition from WB to GB heater-cooler technologies in our practice. This early analysis suggests that GB heater coolers may be safely adopted to mitigate the risks of nontuberculous mycobacterium infections for cardiac surgical patients.Keywords
This publication has 16 references indexed in Scilit:
- Hypothermic Circulatory Arrest in Adult Aortic Arch Surgery: A Review of Hypothermic Circulatory Arrest and its Anesthetic ImplicationsJournal of Cardiothoracic and Vascular Anesthesia, 2023
- Deep Versus Moderate Hypothermia in Acute Type A Aortic Dissection: A Propensity-Matched AnalysisHeart, Lung and Circulation, 2022
- The Evolution of Temperature Management for Cardiac Surgery: A Historical PerspectiveJournal of Cardiothoracic and Vascular Anesthesia, 2022
- STS/SCA/AmSECT/SABM Update to the Clinical Practice Guidelines on Patient Blood ManagementThe Annals of Thoracic Surgery, 2021
- Net Prime Volume Is Associated with Increased Odds of Blood TransfusionThe Journal of ExtraCorporeal Technology, 2019
- Insidious Risk of SevereMycobacterium chimaeraInfection in Cardiac Surgery PatientsClinical Infectious Diseases, 2016
- The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology: Clinical Practice Guidelines for Cardiopulmonary Bypass—Temperature Management During Cardiopulmonary BypassThe Annals of Thoracic Surgery, 2015
- Prolonged Outbreak of Mycobacterium chimaera Infection After Open-Chest Heart SurgeryClinical Infectious Diseases, 2015
- Biomedical Transport Processes2012
- Cross-clamp time is an independent predictor of mortality and morbidity in low- and high-risk cardiac patientsInternational Journal of Surgery, 2011