Formulas to Explain Popular Oscillometric Blood Pressure Estimation Algorithms
Open Access
- 21 November 2019
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 1415
Abstract
Oscillometry is the blood pressure (BP) measurement principle of most automatic cuff devices. The oscillogram (which is approximately the blood volume oscillation amplitude-external pressure function) is measured, and BP is then estimated via an empirical algorithm. The objective was to establish formulas to explain three popular empirical algorithms in the literature—the maximum amplitude, derivative, and fixed ratio algorithms. A mathematical model of the oscillogram was developed and analyzed to derive parametric formulas for explaining each algorithm. Exemplary parameter values were obtained by fitting the model to measured oscillograms. The model and formulas were validated by showing that their predictions correspond to measurements. The formula for the maximum amplitude algorithm indicates that it yields a weighted average of systolic and diastolic BP (0.45 and 0.55 weighting) instead of commonly assumed mean BP. The formulas for the derivative algorithm indicate that it can accurately estimate systolic and diastolic BP (40). The established formulas allow for easy and complete interpretation of perhaps the three most popular oscillometric BP estimation algorithms in the literature while providing new insights. The model and formulas may also be of some value toward improving the accuracy of automatic cuff BP measurement devices.Keywords
Funding Information
- National Institutes of Health
This publication has 29 references indexed in Scilit:
- Error Mechanisms of the Oscillometric Fixed-Ratio Blood Pressure Measurement MethodAnnals of Biomedical Engineering, 2012
- Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical modelBioMedical Engineering OnLine, 2012
- 50 years a biomedical engineer remembering a long and fascinating journeyBioMedical Engineering OnLine, 2012
- Errors of oscillometric blood pressure measurement as predicted by simulationBlood Pressure Monitoring, 2011
- How to assess mean blood pressure properly at the brachial artery levelJournal Of Hypertension, 2007
- Noninvasive Arterial Blood Pressure and Mechanics2006
- A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurementIEEE Transactions on Biomedical Engineering, 1996
- Update on Methods & Simulators for Evaluation of Noninvasive Blood Pressure MonitorsJournal of Clinical Engineering, 1994
- Characterization of the oscillometric method for measuring indirect blood pressureAnnals of Biomedical Engineering, 1982
- The Meaning of the Point of Maximum Oscillations in Cuff Pressure in the Indirect Measurement of Blood Pressure—Part IIJournal of Biomechanical Engineering, 1980