Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?
Authors:
- W BirchallWBW Birchall
- A BedggoodABA Bedggood
- A P WellsAWA P Wells
Open Access
- 27 January 2006
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 21 (3) , 402-407
Abstract
To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.Keywords
This publication has 23 references indexed in Scilit:
- A randomised, prospective study comparing trabeculectomy with viscocanalostomy with adjunctive antimetabolite usage for the management of open angle glaucoma uncontrolled by medical therapyBritish Journal of Ophthalmology, 2004
- Surgery for glaucomaBritish Journal of Ophthalmology, 2003
- The National Survey of Trabeculectomy. III. Early and late complicationsEye, 2002
- Nonpenetrating glaucoma surgeryOphthalmology, 2001
- The risk profile of glaucoma filtration surgeryCurrent Opinion in Ophthalmology, 1999
- Tight versus loose scleral flap closure in trabeculectomy surgeryDocumenta Ophthalmologica, 1993
- Is high initial aqueous outflow of benefit in trabeculectomy?Eye, 1993
- Die Beziehung zwischen Druckregulierung und anatomischer Lokalisation sowie Trepangröße bei der Goniotrepanation - Eine prospektive StudieKlinische Monatsblätter für Augenheilkunde, 1981
- The Place of Trabeculectomy in the Treatment of GlaucomaOphthalmology, 1981
- TrabeculectomyAmerican Journal of Ophthalmology, 1968