Use of Ga for mass bias correction for the accurate determination of copper isotope ratio in the NIST SRM 3114 Cu standard and geological samples by MC-ICPMS
- 24 March 2015
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (1) , 280-287
Abstract
The absolute determination of the Cu isotope ratio in NIST SRM 3114 based on a regression mass bias correction model is performed for the first time with NIST SRM 944 Ga as the calibrant. A value of 0.4471 ± 0.0013 (2SD, n = 37) for the 65Cu/63Cu ratio was obtained with a value of +0.18 ± 0.04‰ (2SD, n = 5) for δ65Cu relative to NIST 976. The availability of the NIST SRM 3114 material, now with the absolute value of the 65Cu/63Cu ratio and a δ65Cu value relative to NIST 976 makes it suitable as a new candidate reference material for Cu isotope studies. In addition, a protocol is described for the accurate and precise determination of δ65Cu values of geological reference materials. Purification of Cu from the sample matrix was performed using the AG MP-1M Bio-Rad resin. The column recovery for geological samples was found to be 100 ± 2% (2SD, n = 15). A modified method of standard-sample bracketing with internal normalization for mass bias correction was employed by adding natural Ga to both the sample and the solution of NIST SRM 3114, which was used as the bracketing standard. An absolute value of 0.4470 ± 0.0013 (2SD, n = 37) for 65Cu/63Cu quantified in this study was used to calibrate the 69Ga/71Ga ratio in the two adjacent bracketing standards of SRM 3114, their average value of 69Ga/71Ga was then used to correct the 65Cu/63Cu ratio in the sample. Measured δ65Cu values of 0.18 ± 0.04‰ (2SD, n = 20), 0.13 ± 0.04‰ (2SD, n = 9), 0.08 ± 0.03‰ (2SD, n = 6), 0.01 ± 0.06 (2SD, n = 4) and 0.26 ± 0.04‰ (2SD, n = 7) were obtained for five geological reference materials of BCR-2, BHVO-2, AGV-2, BIR-1a, and GSP-2, respectively, in agreement with values obtained in previous studies.Keywords
This publication has 41 references indexed in Scilit:
- Accurate and precise determination of isotopic ratios by MC‐ICP‐MS: A reviewMass Spectrometry Reviews, 2009
- Copper isotopes as monitors of redox processes in hydrothermal mineralizationGeochimica et Cosmochimica Acta, 2006
- Copper-containing plastocyanin used for electron transport by an oceanic diatomNature, 2006
- Zn and Cu isotopic variations in chondrites and iron meteorites: Early solar nebula reservoirs and parent-body processesGeochimica et Cosmochimica Acta, 2005
- Precise and accurate isotopic measurements using multiple-collector ICPMSGeochimica et Cosmochimica Acta, 2004
- High-precision Cu and Zn isotope analysis by plasma source mass spectrometryJournal of Analytical Atomic Spectrometry, 2004
- Copper isotope ratios in magmatic and hydrothermal ore-forming environmentsChemical Geology, 2003
- Determination of natural Cu-isotope variation by plasma-source mass spectrometry: implications for use as geochemical tracersChemical Geology, 2000
- Natural variations in the abundance ratio and the atomic weight of copperJournal of Geophysical Research, 1965