Thin fiber-based Mach–Zehnder interferometric sensor for measurement of liquid level, refractive index, temperature, and axial strain
Authors:
- Wei LiuWLWei Liu
- Xuqiang WuXWXuqiang Wu
- Gang ZhangGZGang Zhang
- Shili LiSLShili Li
- Cheng ZuoCZCheng Zuo
- Wujun ZhangWZWujun Zhang
- Benli YuBYBenli Yu
- 19 February 2020
- journal article
- research article
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (6) , 1786-1792
Abstract
An all-fiber Mach–Zehnder interferometric sensor capable of measuring liquid level, refractive index (RI), temperature, and axial strain is proposed and experimentally demonstrated. The proposed sensor is based on a fiber ball–thin fiber (TF)–core-offset structure sandwiched between two standard single-mode fibers. The variations of ambient liquid level, RI, temperature, and axial strain cause the change of phase difference between the cladding modes and the core mode, which leads to the shift of interference spectrum. The wavelength shifts of three resonant dips in the transmission spectrum are used to investigate the sensing characteristics of the sensor. Experimental results show that the sensor with TF length of 20 mm exhibits high RI and liquid-level sensitivities of − 131.7092 n m / R I U and − 120.7 p m / m m at a wavelength of 1589.5 nm. Meanwhile, the sensor is insensitive to temperature and axial strain, and the maximum sensitivities are 0.0390 nm/°C and − 4 . 84 × 10 − 4 n m / µ ε , respectively. In addition, the sensor shows superiority in measuring multiple parameters simultaneously.Keywords
Funding Information
- National Natural Science Foundation of China (51627804)
- National Key R&D Program of China (2016YFC0301902)
- Provincial Key R&D Program of Anhui (1804a0802214)
This publication has 17 references indexed in Scilit:
- Simultaneous Measurement of Refractive Index and Temperature Based on a Peanut-Shape Structure In-Line Fiber Mach–Zehnder InterferometerIEEE Sensors Journal, 2018
- Single-mode all-fiber structured modal interference for temperature and refractive index sensingLaser Physics Letters, 2017
- Simultaneous Measurement of Liquid Level and Temperature Using Tilted Fiber Bragg GratingIEEE Sensors Journal, 2015
- Simultaneous Measurement of Refractive Index and Temperature Based on Modal InterferenceIEEE Sensors Journal, 2014
- In-fiber quasi-Michelson interferometer with a core–cladding-mode fiber end-face mirrorApplied Optics, 2013
- Long-Period Fiber Grating Sensors for the Measurement of Liquid Level and Fluid-Flow VelocitySensors, 2012
- Tapered fibre Mach-Zehnder interferometer for simultaneous measurement of liquid level and temperatureElectronics Letters, 2011
- Simultaneous Measurement of Refractive Index, Temperature, and Strain Using Etched-Core Fiber Bragg Grating SensorsIEEE Photonics Technology Letters, 2010
- Detection of liquid-level variation using a side-polished fiber Bragg gratingOptics & Laser Technology, 2010
- Simultaneous Measurement of Refractive Index and Temperature by Using Dual Long-Period Gratings With an Etching ProcessIEEE Sensors Journal, 2007