Effect of catheter size and injection rate of contrast agent on enhancement and image quality for triple‐phase helical computed tomography of the liver in small dogs
Authors:
- 27 July 2017
- journal article
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 58 (6) , 664-670
Abstract
Rapid contrast injection is recommended for triple‐phase helical computed tomography (CT) of the liver. However, a large‐gauge catheter is needed for faster contrast injection and this is not practical for small breed dogs or cats. The purpose of this crossover group study was to evaluate applicability of a lower injection rate with a small‐gauge (G) catheter for triple‐phase hepatic CT in small dogs. Triple‐phase CT images were acquired for six beagle dogs using three protocols: an injection rate of 1.5 ml/s with a 24 G catheter, 3.0 ml/s with a 22 G catheter, and 4.5 ml/s with a 20 G catheter. Enhancement of the aorta, portal vein, and hepatic parenchyma was measured in each phase (arterial, portal, and delayed) and image quality was scored subjectively by two observers. Injection duration, time to scan delay, and time to peak enhancement were also recorded. Contrast injection duration decreased with a higher injection rate (n = 6, P ≤ 0.01), but time to peak enhancement and time to scan delay were not significantly affected by injection rates and catheter sizes. Contrast injection rate did not significantly affect aortic, portal, and hepatic enhancement. In addition, separation between each phase and quality of images was subjectively scored as good regardless of injection rate. Findings from the current study supported using an injection rate of 1.5 ml/s with a catheter size of 24 G for triple‐phase hepatic CT in small dogs (weight < 12 kg).Keywords
Funding Information
- Chonnam National University
- National Research Foundation of Korea
This publication has 17 references indexed in Scilit:
- TRIPLE‐PHASE HELICAL COMPUTED TOMOGRAPHY IN DOGS WITH HEPATIC MASSESVeterinary Radiology & Ultrasound, 2013
- The efficacy of contrast protocol in hepatic dynamic computed tomography: multicenter prospective study in community hospitalsSpringerPlus, 2013
- CT Contrast Media and Applications2011
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- Safety of Power Injector Use in Children as Measured by Incidence of ExtravasationAmerican Journal of Roentgenology, 2006
- Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient WeightRadiology, 2004
- Peak Contrast Enhancement in CT and MR Angiography: When Does It Occur and Why? Pharmacokinetic Study in a Porcine ModelRadiology, 2003
- Effects of injection rates of contrast material on arterial phase hepatic CT.American Journal of Roentgenology, 1998
- Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model.Radiology, 1998
- Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing.American Journal of Roentgenology, 1996