Treatment of Distal Femur Fractures With the DePuy-Synthes Variable Angle Locking Compression Plate
- 1 September 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 33 (9) , 432-437
Abstract
Objectives: To determine the failure rate of the DePuy-Synthes variable angle locking compression curved condylar plate (VA-LCP) and quantify failure modes. Design: Retrospective review. Setting: Level I Trauma Center. Patients/Participants: One hundred thirteen patients with 118 OTA/AO classification 33A and 33C distal femoral fractures were included in the study. Intervention: Internal fixation using only the DePuy-Synthes VA-LCP plate. Main Outcome Measurements: Primary outcomes included mechanical failure rate of the DePuy-Synthes VA-LCP plate in open and closed fractures. Secondary outcomes included overall failure rate of treatment, risk factors for mechanical failure, and the specific location of failure: loss of fixation in the proximal segment, implant failure over the working length, or failure of locking screw fixation distally. Results: There were 11 total failures (9.3%) in 118 fractures. Failure rates for the closed and open fracture groups were 5.4% and 15.9%, respectively. Twenty patients (16.9%) required reoperation to promote union. Open fractures (P = 0.00475), the presence of medial metaphyseal comminution (P = 0.037), the length of the zone of comminution (P = 0.037), and plate length (P = 0.0096) were significantly higher in those with implant failure. Most failures (63.6%) were in the working length of the implant. Conclusions: The use of the Synthes VA-LCP is a viable option in distal femoral fractures and has an acceptable failure rate and reoperation to promote union rate. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 13 references indexed in Scilit:
- A double-plating approach to distal femur fracture: A clinical studyInjury, 2017
- Outcomes of Distal Femur Nonunions Treated With a Combined Nail/Plate Construct and Autogenous Bone GraftingJournal of Orthopaedic Trauma, 2017
- Addition of a Medial Locking Plate to an In Situ Lateral Locking Plate Results in Healing of Distal Femoral NonunionsClinical Orthopaedics and Related Research, 2016
- In responseJournal of Orthopaedic Trauma, 2016
- Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur PlateJournal of Orthopaedic Trauma, 2016
- Risk Factors for Failure of Locked Plate Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2014
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- Results of Polyaxial Locked-Plate Fixation of Periarticular Fractures of the KneeJournal of Bone and Joint Surgery, 2007
- The epidemiology of fractures of the distal femurInjury, 2000
- Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bonesJournal of Bone and Joint Surgery, 1976