A New Device to Automate the Monitoring of Critical Patients’ Urine Output
Open Access
- 1 January 2014
- journal article
- research article
- Published by Hindawi Limited in BioMed Research International
- Vol. 2014, 1-8
Abstract
Urine output (UO) is usually measured manually each hour in acutely ill patients. This task consumes a substantial amount of time. Furthermore, in the literature there is evidence that more frequent (minute-by-minute) UO measurement could impact clinical decision making and improve patient outcomes. However, it is not feasible to manually take minute-by-minute UO measurements. A device capable of automatically monitoring UO could save precious time of the healthcare staff and improve patient outcomes through a more precise and continuous monitoring of this parameter. This paper presents a device capable of automatically monitoring UO. It provides minute by minute measures and it can generate alarms that warn of deviations from therapeutic goals. It uses a capacitive sensor for the measurement of the UO collected within a rigid container. When the container is full, it automatically empties without requiring any internal or external power supply or any intervention by the nursing staff. In vitro tests have been conducted to verify the proper operation and accuracy in the measures of the device. These tests confirm the viability of the device to automate the monitoring of UO.Keywords
Funding Information
- Spanish MEC (TIN2009-14372-C03-03)
This publication has 25 references indexed in Scilit:
- Association of AKI with Adverse Outcomes in Burned Military CasualtiesClinical Journal of the American Society of Nephrology, 2012
- Secure Remote Health Monitoring with Unreliable Mobile DevicesJournal of Biomedicine and Biotechnology, 2012
- An Assessment of the Acute Kidney Injury Network Creatinine-Based Criteria in Patients Submitted to Mechanical VentilationClinical Journal of the American Society of Nephrology, 2011
- Experimentally Approaching the ICU: Monitoring Outcome‐Based Responses in the Two‐Hit Mouse Model of Posttraumatic SepsisBioMed Research International, 2011
- Accuracy and ease of use of a novel electronic urine output monitoring device compared with standard manual urinometer in the intensive care unitJournal of Critical Care, 2009
- Addressing the flaws of current critical alarms: a fuzzy constraint satisfaction approachArtificial Intelligence in Medicine, 2009
- FLUID RESUSCITATION IN MAJOR BURNSAnz Journal of Surgery, 2006
- Intelligent Alarms for Anaesthesia Monitoring Based on a Fuzzy Logic Approach2002
- Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic ShockNew England Journal of Medicine, 2001
- Intelligent patient monitoring and management systems: a reviewIEEE Engineering in Medicine and Biology Magazine, 1993