We compared the performance of an ultramicrofibre (UMF)-based system with or without a novel copper-based biocide (CuWB50) with standard cleaning using Actichlor Plus in four hospital wards in a crossover study design, and analysed our results using univariate and multivariate statistics. We measured total viable counts (TVCs) and ATP levels in 10 near-patient sites three times weekly, one hour before and after cleaning. Standard cleaning reduced TVCs further than UMF cleaning with water, but UMF cleaning with CuWB50 produced equivalent TVC reduction. Furthermore we identified a ‘residual effect’ with UMF + CuWB50, conferring TVC suppression for up to a week after application. ATP results did not correlate with TVCs. We conclude that UMF-based cleaning with CuWB50 results in TVC reductions equivalent to hypochlorite-based standard cleaning, with the added advantages of a residual effect that keeps TVCs lower between cleaning rounds.Keywords
This publication has 19 references indexed in Scilit:
- The role of environmental cleaning in the control of hospital-acquired infectionJournal of Hospital Infection, 2009
- Decontamination of laundry at low temperature with CuWB50, a novel copper-based biocidal compoundAmerican Journal of Infection Control, 2009
- A comparison of the antibacterial efficacy and cytotoxicity to cultured human skin cells of 7 commercial hand rubs and Xgel, a new copper-based biocidal hand rubAmerican Journal of Infection Control, 2009
- Microbiologic evaluation of microfiber mops for surface disinfectionAmerican Journal of Infection Control, 2007
- A microbiological evaluation of hospital cleaning methodsInternational Journal of Environmental Health Research, 2007
- Three novel highly charged copper-based biocides: safety and efficacy against healthcare-associated organismsJournal of Antimicrobial Chemotherapy, 2007
- Monitoring the effectiveness of cleaning in four British hospitalsAmerican Journal of Infection Control, 2007
- A laboratory evaluation of the decontamination properties of microfibre clothsJournal of Hospital Infection, 2006
- Contamination, Disinfection, and Cross-Colonization: Are Hospital Surfaces Reservoirs for Nosocomial Infection?Clinical Infectious Diseases, 2004
- Ward floors and other surfaces as reservoirs of hospital infectionEpidemiology and Infection, 1967