Ceftriaxone is a cephalosporin antibiotic drug used as first-line treatment for a number of bacterial diseases. Ceftriaxone belongs to the third generation of antibiotics and is available as an intramuscular or intravenous injection. Previously published pharmacokinetic studies have used high-performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) for the quantification of ceftriaxone. This study aimed to develop and validate a bioanalytical method for the quantification of ceftriaxone in human plasma using liquid chromatography followed by tandem mass spectrometry (LC-MS/MS). Sample preparation was performed by protein precipitation of 100 µl plasma sample in combination with phospholipid-removal techniques to minimize matrix interferences. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C18 column with 10 mM ammonium formate containing 2% formic acid: acetonitrile as mobile phase at a flow rate of 0.4 ml/min with a total run time of 10 minutes. Both the analyte and cefotaxime (internal standard) were quantified using the positive electrospray ionization (ESI) mode and selected reaction monitoring (SRM) for the precursor-product ion transitions m/z 555.0→396.1 for ceftriaxone and 456.0→324.0 for cefotaxime. The method was validated over the concentration range of 1.01-200 μg/ml. Calibration response showed good linearity (correlation coefficient > 0.99) and matrix effects were within the ±15% limit in 6 different lots of sodium heparin plasma tested. However, citrate phosphate dextrose plasma resulted in a clear matrix enhancement of 24% at the low concentration level, which was not compensated for by the internal standard. Different anticoagulants (EDTA, heparin and citrate phosphate dextrose) also showed differences in recovery. Thus, it is important to use the same anticoagulant in calibration curves and clinical samples for analysis. The intra-assay and inter-assay precision were less than 5% and 10%, respectively, and therefore well within standard regulatory acceptance criterion of ±15%.Keywords
Funding Information
- Bill and Melinda Gates Foundation (OPP1133769)
- Wellcome Trust (104926)
This publication has 27 references indexed in Scilit:
- Simultaneous Determination of 12 β-Lactam Antibiotics in Human Plasma by High-Performance Liquid Chromatography with UV Detection: Application to Therapeutic Drug MonitoringAntimicrobial Agents and Chemotherapy, 2011
- Population pharmacokinetics of ceftriaxone in critically ill septic patients: a reappraisalBritish Journal of Clinical Pharmacology, 2011
- Microanalysis of β-Lactam Antibiotics and Vancomycin in Plasma for Pharmacokinetic Studies in NeonatesAntimicrobial Agents and Chemotherapy, 2009
- Monitoring phospholipids for assessment of ion enhancement and ion suppression in ESI and APCI LC/MS/MS for chlorpheniramine in human plasma and the importance of multiple source matrix effect evaluationsJournal of Chromatography B, 2008
- Understanding Isotopic Distributions in Mass SpectrometryJournal of Chemical Education, 2006
- The Impact of Antimicrobial Resistance on Health and Economic OutcomesClinical Infectious Diseases, 2003
- The pharmacokinetics of once-daily dosing of ceftriaxone in critically ill patientsJournal of Antimicrobial Chemotherapy, 2001
- Pharmacokinetics of Ceftriaxone in Patients Undergoing Continuous Veno-Venous HemofiltrationThe Journal of Clinical Pharmacology, 1996
- Pharmacokinetics and tolerance of ceftriaxone in humans after single-dose intramuscular administration in water and lidocaine diluentsAntimicrobial Agents and Chemotherapy, 1982
- Pharmacokinetics of ceftriaxone in humansAntimicrobial Agents and Chemotherapy, 1981