Randomized clinical trial of suction versus standard clearance of the diathermy plume
Authors:
- 3 July 2003
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 90 (9) , 1068-1071
Abstract
Background: Diathermy smoke contains complex hydrocarbons and organic material, and may contain viable tumour cells or viral particles. These particles measure from 0·05 to more than 25 µm, and long‐term exposure to such particles may have adverse effects on health. This study investigated whether a suction clearance device reduces the amount of smoke reaching the surgeon's mask. Methods: This was a randomized clinical trial in which subjects were randomized to standard diathermy equipment (group 1) or a diathermy smoke extraction system (group 2). All patients underwent thyroid or parathyroid surgery with standard anterior cervical collar incision and division of the strap muscles. The difference in the amount of smoke reaching the level of the operator's mask was measured by means of an aerosol monitor. Results: Fifteen patients were randomized to each group. The mean amount of smoke detected at the level of the operator's mask was 0·137 mg/m3 in group 1 and 0·012 mg/m3 in group 2 (P < 0·001). The maximum amount detected was 2·411 and 0·255 mg/m3 respectively (P < 0·001). There were no significant differences between the groups in terms of incision time or background particles measured before and after surgery. There was no correlation between gland weight and incision time or amount of smoke detected. Conclusion: Suction clearance of the diathermy plume resulted in a significant reduction in the amount of smoke reaching the level of the operator's mask. Although the risk of diathermy smoke inhalation is currently unknown, use of such a system appears advisable. Copyright © 2003 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.Keywords
This publication has 11 references indexed in Scilit:
- Cells are present in the smoke created during laparoscopic surgeryBritish Journal of Surgery, 1997
- Chemical composition and potential hazards of electrocautery smokeBritish Journal of Surgery, 1996
- THE AETIOLOGY, INVESTIGATION AND MANAGEMENT OF SURGICAL DISORDERS OF THE THYROID GLANDAnz Journal of Surgery, 1996
- Preliminary study of electrocautery smoke particles produced in vitro and during laparoscopic proceduresSurgical Endoscopy, 1996
- Respirable Aerosol Sampler Performance TestingAIHA Journal, 1994
- EXPOSURE TO BLOOD-CONTAINING AEROSOLS IN THE OPERATING ROOM: A PRELIMINARY STUDYAIHA Journal, 1993
- Aerosol penetration and leakae characteristics of masks used in the health care industryAmerican Journal of Infection Control, 1993
- Effects of plume produced by the Nd:YAG laser and electrocautery on the respiratory systemLasers in Surgery and Medicine, 1993
- Presence of human immunodeficiency virus DNA in laser smokeLasers in Surgery and Medicine, 1991
- The effects of laser smoke on the lungs of ratsAmerican Journal of Obstetrics and Gynecology, 1987