Abstract
Inductively-coupled wireless power transfer (IWPT) is promising to power a freely moving capsule robot (CR) continuously. Existing IWPT system for this application normally adopts a single-layer Helmholtz coil (SHC), which can generate a uniform alternating magnetic field (AMF) to cover the CR workspace, but leads to a low power transfer efficiency (PTE). To improve the PTE, this paper proposes a novel double-layer Helmholtz coil (DHC). The DHC is composed of two in-parallel connected SHCs that have identical coil turns and winding directions but different diameters. To design and optimize the DHC, a dedicated analytical model, is built and verified. A comparison between the DHC and SHC is also conducted, which shows that the DHC can not only generate a uniform AMF to cover a larger region, but its power consumption is lower when the generated AMF is identical, thus improving the PTE. Finally, the DHC is used to power a three-dimensional receiving coil, and the achieved PTE is in a range of 7.58%∼17.41%, higher than that when using the SHC, which is in a range of 6.74%∼14.92%.
Funding Information
  • National Natural Science Foundation of China (52275038, 61803347)
  • Shanxi Province Science Foundation for Excellent Youth (202203021224007)
  • Key Research and Development Plan of Shanxi Province of China (201903D321164, 2022ZDYF082)
  • Opening Foundation of Shanxi Key Laboratory of Advanced Manufacturing Technology (XJZZ202101)

This publication has 28 references indexed in Scilit: