Abstract
Although a large variety of animal models for acute ischemia and acute heart failure exist, valuable models for studies on the effect of ventricular assist devices in chronic heart failure are scarce. We established a stable and reproducible animal model of chronic heart failure in sheep and aimed to investigate the hemodynamic changes of this animal model of chronic heart failure in sheep. In five sheep (n = 5, 77 ± 2 kg), chronic heart failure was induced under flouroscopic guidance by multiple sequential microembolization through bolus injection of polysterol microspheres (90 µm, n = 25.000) into the left main coronary artery. Coronary microembolization (CME) was repeated up to three times in 2 to 3‐week intervals until animals started to develop stable signs of heart failure. During each operation, hemodynamic monitoring was performed through implantation of central venous catheter (central venous pressure [CVP]), arterial pressure line (mean arterial pressure [MAP]), implantation of a right heart catheter {Swan‐Ganz catheter (mean pulmonary arterial pressure [PAPmean])}, pulmonary capillary wedge pressure (PCWP), and cardiac output [CO]) as well as pre‐ and postoperative clinical investigations. All animals were followed for 3 months after first microembolization and then sacrificed for histological examination. All animals developed clinical signs of heart failure as indicated by increased heart rate (HR) at rest (68 ± 4 bpm [base] to 93 ± 5 bpm [3 mo][P < 0.05]), increased respiratory rate (RR) at rest (28 ± 5 [base] to 38 ± 7 [3 mo][P < 0.05]), and increased body weight 77 ± 2 kg to 81 ± 2 kg (P < 0.05) due to pleural effusion, peripheral edema, and ascites. Hemodynamic signs of heart failure were revealed as indicated by increase of HR, RR, CVP, PAP, and PCWP as well as a decrease of CO, stroke volume, and MAP 3 months after the first CME. Multiple sequential intracoronary microembolization can effectively induce myocardial dysfunction with clinical and hemodynamic signs of chronic ischemic cardiomyopathy. The present model may be suitable in experimental work on heart failure and left ventricular assist devices, for example, for studying the impact of mechanical unloading, mechanisms of recovery, and reverse remodeling.Keywords
This publication has 14 references indexed in Scilit:
- Epidemiology of Heart Failure and Left Ventricular Systolic Dysfunction after Acute Myocardial Infarction: Prevalence, Clinical Characteristics, and Prognostic ImportanceThe American Journal of Cardiology, 2006
- Coronary microembolization*1Journal of Molecular and Cellular Cardiology, 2004
- Coronary Microembolization: the Role of TNF- α in Contractile DysfunctionJournal of Molecular and Cellular Cardiology, 2002
- Atherosclerotic Plaque Burden and CK-MB Enzyme Elevation After Coronary InterventionsCirculation, 2000
- Effect of Rotablator Atherectomy and Adjunctive Balloon Angioplasty on Coronary Blood FlowCirculation, 1997
- Prevalence and Timing of Regional Myocardial Dysfunction After Rotational Coronary AtherectomyJACC, 1996
- Hemodynamic, left ventricular structural and hormonal changes after discrete myocardial damage in the dogJACC, 1992
- Plaque fissuring--the cause of acute myocardial infarction, sudden ischaemic death, and crescendo angina.Heart, 1985
- The renin-angiotensin-aldosterone system in congestive failure in conscious dogs.Journal of Clinical Investigation, 1976
- Experimental myocardial ischemia and infarctionThe American Journal of Cardiology, 1972